预制混凝土柱法兰灌浆节点的连接设计及试验验证

Connection design and experimental verification of grouted flange joint for prefabricated concrete columns

浏览量:

关键词:

预制混凝土柱;干式连接;免支撑施工;法兰灌浆连接节点;低周往复加载;承载能力;变形能力

Key words:

Prefabricated concrete column; Dry connection; Unsupported construction; Grouted flange connection joint; Low cyclic reversed loading; Bearing capacity; Deformation capacity

刊期:

2026年第3期

DOI:

10.19761/j.1000-4637.24090492

文章编号:

基金项目:

Abstract: In order to solve the problems associated with dry connection and unsupported construction in prefabricated concrete columns, a grouted flange connection joint for prefabricated concrete columns was proposed. The design method was studied, and p

作者:

邬程欢1,王朴炎1,周 剑2,刘 刚3,王振兴2,屠 锋3,钟晓波3, 舒 恺1,钟维军1,周勋甜1

单位:

1.国网浙江省电力有限公司宁波供电公司,浙江 宁波 315020;2.中建研科技股份有限公司,北京 100013;3.国网浙江省电力有限公司,浙江 杭州 311500

摘要

摘   要:为了解决预制混凝土柱干式连接和免支撑施工问题,提出了一种预制混凝土柱法兰灌浆连接节点,研究了其设计方法,并设计制作了法兰灌浆连接预制柱试件,对其进行了低周往复加载试验,分析了试件的破坏形态和受力性能,并与矩形钢管通长设置试件(对照组)进行了对比。结果表明:法兰灌浆连接预制柱的破坏模式为典型压弯破坏,塑性铰首先出现在预制混凝土柱身纵筋与钢连接件的连接截面,与设计预期一致,可实现法兰灌浆连接节点“强连接弱构件”设计;与对照组试件相比,法兰灌浆连接预制柱试件的骨架曲线走势、承载能力和变形能力基本一致,可视为“等强连接”,同时也验证了设计方法的正确性和连接构造的可靠性;法兰灌浆连接预制柱试件的极限位移角为1/42,位移延性系数为5.5,具有较高的延性水平。采用预制上、下柱法兰灌浆连接可提高装配效率,实现干式连接和免支撑施工,对推动工业化发展具有一定的参考价值。

Abstract: In order to solve the problems associated with dry connection and unsupported construction in prefabricated concrete columns, a grouted flange connection joint for prefabricated concrete columns was proposed. The design method was studied, and prefabricated column specimens with grouted flange connection were designed to conduct low cyclic reversed loading tests. The failure modes and mechanical behaviors of the specimens were analyzed, and the test results were compared with those of rectangular steel pipe specimens (the control group). The results show that the failure mode of the prefabricated column specimens with grouted flange connection is a typical flexural-compression failure, with plastic hinges first developing at the connection section between the longitudinal bars of the prefabricated concrete columns and the steel connectors, which is consistent with the design expectations. This enables the achievement of the "strong connection, weak member" design principle for grouted flange connection joints. Compared with the control group specimens, the prefabricated column specimens with grouted flange connection exhibit nearly identical trends in their skeleton curves, as well as bearing capacity and deformation capacity. This connection can thus be regarded as an "equal-strength connection", which also verifies the correctness of the design method and the reliability of the connection structure. The ultimate displacement angle of the specimens is 1/42, and the displacement ductility coefficient is 5.5, indicating excellent ductility. The use of grouted flange connection joint for prefabricated upper and lower columns can improve assembly efficiency, realize dry connection and unsupported construction, and provide certain reference value for promoting the industrial development of prefabricated concrete structures.

结论

(1)本文通过低周往复加载试验,验证了所设计的干式连接预制上、下柱法兰灌浆连接节点设计方法的正确性、连接构造的可靠性和抗震性能的优越性。
(2)当设计轴压比为0.5时,法兰灌浆连接预制柱试件的破坏形态为压弯破坏,塑性铰首先出现在预制混凝土柱身纵筋与钢连接件连接截面,本文设计方法可实现法兰灌浆连接节点的“强连接弱构件”设计。
(3)与矩形钢管通长设置试件ZZ2相比,法兰灌浆连接预制柱试件YZ1的骨架曲线走势、承载能力、变形能力均相差不大,二者均可可靠传力,可视为“等强连接”。
(4)法兰灌浆连接预制柱试件的承载力实测值与根据GB/T 50010—2010得到的计算值的比值为1.39,说明该试件设计具有一定的安全储备;极限位移角为1/42,位移延性系数为5.5,说明该试件具有较好的抗震性能。

参考文献

[1] 侯光荣,王绪续,吕娜娜,等.新型装配式部分型钢混凝土框架梁柱节点抗震性能试验研究[J].建筑结构,2018,48(7):27-32.

[2] 黎威昱,朱礼敏,周剑,等.新型装配整体式钢连接混合框架结构设计要点与工程应用[J].建筑结构,2023,53(增刊1):1106-1112.
[3] 中华人民共和国住房和城乡建设部.装配式混凝土建筑技术标准:GB/T 51231—2016[S].北京:中国建筑工业出版社,2017.
[4] 中华人民共和国住房和城乡建设部.装配式混凝土结构技术规程:JGJ 1—2014[S].北京:中国建筑工业出版社,2014.
[5] 黄小坤,田春雨.预制装配式混凝土结构研究[J].住宅产业,2010(9):28-32.
[6] 陈骏,彭畅,李超,等.装配式建筑发展概况及评价标准综述[J].建筑结构,2022,52(增刊2):1503-1508.
[7] 颜孙杰,董超,赵士瑞.装配式混凝土剪力墙结构竖向接缝干式连接技术研究进展[J].工程建设与设计,2024(1):220-222.
[8] 高海洋.预制劲性钢管混凝土构件连接及节点受力性能研究[D].沈阳:东北大学,2020.
[9] 鲁余勇,薛彦涛.配置U形阻尼器的全装配式混凝土框架结构抗震性能试验研究[J].建筑结构学报,2023,44(增刊2):240-249.
[10] 黄世晅,舒恺,朱云祥,等.预制柱高强度螺栓法兰连接节点抗震性能试验研究[J].建筑科学,2023,39(7):64-71.
[11] 中华人民共和国住房和城乡建设部.钢结构设计标准:GB 50017—2017[S].北京:中国建筑工业出版社,2017.
[12] 中华人民共和国住房和城乡建设部.混凝土结构设计标准(2024年版):GB/T 50010—2010[S].北京:中国建筑工业出版社,2010.
[13] 中华人民共和国国家质量监督检验检疫总局,中国国家标准化管理委员会.六角薄螺母:GB/T 6172.1—2016[S].北京:中国标准出版社,2016.
[14] 中华人民共和国住房和城乡建设部.高耸结构设计标准:GB 50135—2019[S].北京:中国计划出版社,2019.
[15] 但泽义.钢结构设计手册[M].北京:中国建筑工业出版社,2018.
[16] 中华人民共和国住房和城乡建设部.混凝土结构试验方法标准:GB/T 50152—2012[S].北京:中国建筑工业出版社,2012.
[17] 国家市场监督管理总局,国家标准化管理委员会.金属材料 拉伸试验 第1部分:室温试验方法:GB/T 228.1—2021[S].北京:中国标准出版社,2021.
[18] 中华人民共和国住房和城乡建设部.建筑抗震试验规程:JGJ/T 101—2015[S].北京:中国建筑工业出版社,2015.
[19] 中华人民共和国住房和城乡建设部,中华人民共和国国家质量监督检验检疫总局.建筑抗震设计标准(2024年版):GB/T 50011—2010[S].北京:中国建筑工业出版社,2010.

引用本文

邬程欢,王朴炎,周剑,等.预制混凝土柱法兰灌浆节点的连接设计及试验验证[J].混凝土与水泥制品,2026,53(3):68-74,92. WU C H,WANG P Y,ZHOU J,et al.Connection design and experimental verification of grouted flange joint for prefabricated concrete columns[J].China Concrete and Cement Products,2026,53(3):68-74,92 (in Chinese).


上一个: 橡胶集料混凝土三点弯曲试件损伤破坏的声发射表征

下一个: 基于ABAQUS的GFRP管约束UHPC组合柱轴压性能研究

相关文件