新型泡沫混凝土轻质墙板外挂节点力学性能试验研究
Experimental Research on Mechanical Properties of New Foam Concrete External Precast Wallboard
2015年第11期
泡沫混凝土;外挂墙板;节点预埋件;承载力
Foam concrete; External precast wall panel; Embedded node; Capacity
2015年第11期
1000-4637(2015)11-70-05
谷 倩,周 珣,舒 松,李 博
武汉理工大学土木工程与建筑学院,430070

谷 倩,周 珣,舒 松,李 博

浏览量:
1000
摘 要:外挂墙板在建筑结构中广泛应用,新型泡沫混凝土外挂墙板与框架的连接节点对这种结构的安全性及可靠度有重要的影响。为研究该连接节点的受力机理及破坏模式,对两种配合比的泡沫混凝土分别预埋两种不同形式的节点,对其进行节点抗弯试验以及节点抗剪试验研究,系统对比不同形式的连接节点以及不同配合比的泡沫混凝土墙板对节点承载力的影响,分析墙板在荷载作用下的裂缝开展情况以及荷载-位移曲线。试验结果表明:双面钢板节点有良好的承载力、节点破坏后于墙板本身破坏,能实现墙板与框架安全有效的连接;在预埋双面钢板节点情况下,无陶粒配合比的泡沫混凝土与预埋节点的协同工作性能优于陶粒配合比的泡沫混凝土。 Abstract:External precast wall panels are widely used in building structure, the connection node between the new foam concrete external precast wall panels and framework have an important impact on the safety and reliability. To study the force mechanisms and failure modes of connections node, different foam concrete with mix proportion are used by two different embedded forms of connection node, the investigation for bending and shearing test of connections is carried out. Compared with different forms of node and different mix proportion of foam concrete wall panel by system, which have effects on capacity of node, as well as cracks development of wall panels under loading and the load-displacement curve are analyzed. The results show that, duplex steel node has good capacity, node destroy itself after the damage of wall panels, safe and effective connection between wall panels and frame can be achieved; under the situation of embedded duplex steel node, the work performance of foam concrete with non-ceramic mix proportion and embedded node is better than foam concrete with ceramic mix proportion.
英文名 : Experimental Research on Mechanical Properties of New Foam Concrete External Precast Wallboard
刊期 : 2015年第11期
关键词 : 泡沫混凝土;外挂墙板;节点预埋件;承载力
Key words : Foam concrete; External precast wall panel; Embedded node; Capacity
刊期 : 2015年第11期
DOI :
文章编号 : 1000-4637(2015)11-70-05
基金项目 :
作者 : 谷 倩,周 珣,舒 松,李 博
单位 : 武汉理工大学土木工程与建筑学院,430070

谷 倩,周 珣,舒 松,李 博

摘要
参数
结论
参考文献
引用本文

摘   要:外挂墙板在建筑结构中广泛应用,新型泡沫混凝土外挂墙板与框架的连接节点对这种结构的安全性及可靠度有重要的影响。为研究该连接节点的受力机理及破坏模式,对两种配合比的泡沫混凝土分别预埋两种不同形式的节点,对其进行节点抗弯试验以及节点抗剪试验研究,系统对比不同形式的连接节点以及不同配合比的泡沫混凝土墙板对节点承载力的影响,分析墙板在荷载作用下的裂缝开展情况以及荷载-位移曲线。试验结果表明:双面钢板节点有良好的承载力、节点破坏后于墙板本身破坏,能实现墙板与框架安全有效的连接;在预埋双面钢板节点情况下,无陶粒配合比的泡沫混凝土与预埋节点的协同工作性能优于陶粒配合比的泡沫混凝土。

Abstract:External precast wall panels are widely used in building structure, the connection node between the new foam concrete external precast wall panels and framework have an important impact on the safety and reliability. To study the force mechanisms and failure modes of connections node, different foam concrete with mix proportion are used by two different embedded forms of connection node, the investigation for bending and shearing test of connections is carried out. Compared with different forms of node and different mix proportion of foam concrete wall panel by system, which have effects on capacity of node, as well as cracks development of wall panels under loading and the load-displacement curve are analyzed. The results show that, duplex steel node has good capacity, node destroy itself after the damage of wall panels, safe and effective connection between wall panels and frame can be achieved; under the situation of embedded duplex steel node, the work performance of foam concrete with non-ceramic mix proportion and embedded node is better than foam concrete with ceramic mix proportion.

关键词:
泡沫混凝土;外挂墙板;节点预埋件;承载力
扫二维码用手机看
未找到相应参数组,请于后台属性模板中添加
(1)预埋P1节点的板,在加载过程中,荷载-位移曲线各阶段特征分明,加载初期曲线呈线性发展,之后有明显的塑性变形过程,板中受力钢筋可以达到屈服。在板体发生大变形甚至极限破坏时,预埋件周围混凝土只有少量裂缝产生,节点破坏发生在板极限破坏之后。该节点形式可在工程实际中采用。
(2)预埋P2节点的板,加载过程中,荷载-位移曲线基本呈线性关系。从曲线可以看出,当达到节点极限荷载时,板中的受力钢筋尚未进入屈服阶段,节点处预埋件与板发生脱离,预埋件周围混凝土有明显劈裂现象。
(3)对比配合比1和配合比2板(预埋P1节点),配合比1板较配合比2板抗弯耗能性能提升25%,表明无陶粒泡沫混凝土(配合比1)与钢筋协同工作性能优于掺陶粒的泡沫混凝土(配合比2)。
(4)预埋双面锚板(P1节点)的节点抗剪承载力明显高于预埋单面锚板(P2节点)的节点抗剪承载力。预埋P1节点的板比预埋P2节点的板的节点抗剪承载力提高52.9%(配合比1板)和27.5%(配合比2板),平均提高39.4%。
(5)对比配合比1和配合比2板(预埋P1节点),无陶粒泡沫混凝土板(配合比1)较掺陶粒的泡沫混凝土板(配合比2)的抗剪耗能性能提升37%,表明无陶粒泡沫混凝土与防锈涂层钢筋协同工作性能优于掺陶粒的泡沫混凝土。
[1] 侯和涛,胡肖静,李国强,等.节能复合墙板的极限承载力[J]. 建筑材料学报, 2009,12(1):106-111.
[2] 侯和涛,邱灿星,李国强,等.带节能复合墙板钢框架低周反复荷载试验研究[J].工程力学,2012,29(9):177-184.
[3] Carradine D M, Woeste F E, Dolan J D,et al. Utilizing diaphragm action for wind load design of timberframe and structural insulated panel buildings[J]. ForestProducts Journal, 2004,54(5):73-80.
[4] 李国强,赵欣,孙飞飞,等.钢结构住宅体系墙板及墙板节点足尺试件振动台试验研究[J].地震工程与工程振动,2003,23(1):64-70.
[5] 石永久,王萌,王元清,等.钢框架端板连接半刚性节点受力性能分析[J].工程力学,2011,28(9):51-58.
[6] 郭宏超,郝际平,潘秀珍,等.基于节点连接特性的钢板剪力墙结构数值分析[J].工程力学,2013,30(8):193-198.