苏州混凝土水泥制品研究院有限公司

头部文案

发布时间:2020-01-06 00:00:00
全国建材科技期刊
全国中文核心期刊
中国科技论文统计源期刊
万方数据-数字化期刊群入网期刊
中国学术期刊(光盘版)全文收录期刊
华东地区优秀科技期刊
江苏省期刊方阵“双效期刊”
中国期刊网全文收录期刊
中国科技期刊数据库全文收录期刊
预应力筋材内嵌加固法在混凝土梁中的试验研究
Experimental Study on Near Surface Mounted Reinforcement Method of Prestressed Near Helical Rib Steel Wire in Reinforced Concret
2014年第3期
钢筋混凝土梁;预应力筋材;内嵌加固;承载力
Reinforced concrete beam; Prestressed helical rib steel wire; Near surface mounted reinforcement; Bearing capacity
2014年第3期
1000-4637(2014)03-57-05
国家自然科学基金项目(51108161)、河南省重点学科项目(509919)、河南理工大学博士基金项目(B2010-10)
李慧敏,丁亚红
河南理工大学土木工程学院,焦作454003

李慧敏,丁亚红

浏览量:
1000
摘  要:使用预应力筋材内嵌加固工艺,对10根混凝土梁试件进行了加固后的试验研究。试验证明,预应力筋材内嵌加固法,能够很好地改善混凝土梁试件的整体稳定性,加固后混凝土梁试件的开裂荷载值、屈服荷载值和极限荷载值有显著提高。随加固量及张拉预应力值的不同,加固梁的开裂荷载值提高了72.6%~321.26%,屈服荷载值提高了6.19%~99.09%,极限荷载值提高了46.04%~135.27%。说明预应力筋材内嵌加固法能够有效改善加固梁的延性和安全性能,刚度也有明显提高,对裂缝的产生和发展都有约束作用,同时螺旋肋钢丝的高强性能也得到了充分发挥。Abstract:Theprestressednearsurfacemountedhelicalribsteelwiretensionsystemisadopted,usingtheprocessofslotting,reinforcingandtensioninghelicalribsteelwire,fillingglue,andinthispaper,anexperimentalstudyisconductedon10RCbeamswithprestressednearsurfacemountedhelicalribsteelwire.Theexperimentalresultsindicatethatthismethodcouldimprovetheoverallperformanceofthereinforcedbeams,andfirst-crackload,flexuralload,ultimateloadareincreasedeffectively.Withthenumberofhelicalribsteelwireandprestressedlevel,first-crackloadisincreasedby72.6%~321.26%,flexuralloadisincreasedby6.19%-99.09%,ultimateloadisincreasedby46.04%~135.27%,theeffectisobvious.Thisreinforcingmethodcouldeffectivelyimprovetheductility,safetyperformance,thestiffnessofreinforcedbeam,andtheemergenceanddevelopmentofcrackscouldbeconstrained,andthehighstrengthofhelicalribsteelwirehasbeenfullyplay.
英文名 : Experimental Study on Near Surface Mounted Reinforcement Method of Prestressed Near Helical Rib Steel Wire in Reinforced Concret
刊期 : 2014年第3期
关键词 : 钢筋混凝土梁;预应力筋材;内嵌加固;承载力
Key words : Reinforced concrete beam; Prestressed helical rib steel wire; Near surface mounted reinforcement; Bearing capacity
刊期 : 2014年第3期
DOI :
文章编号 : 1000-4637(2014)03-57-05
基金项目 : 国家自然科学基金项目(51108161)、河南省重点学科项目(509919)、河南理工大学博士基金项目(B2010-10)
作者 : 李慧敏,丁亚红
单位 : 河南理工大学土木工程学院,焦作454003

李慧敏,丁亚红

摘要
参数
结论
参考文献
引用本文

摘   要:使用预应力筋材内嵌加固工艺,对10根混凝土梁试件进行了加固后的试验研究。试验证明,预应力筋材内嵌加固法,能够很好地改善混凝土梁试件的整体稳定性,加固后混凝土梁试件的开裂荷载值、屈服荷载值和极限荷载值有显著提高。随加固量及张拉预应力值的不同,加固梁的开裂荷载值提高了72.6%~321.26%,屈服荷载值提高了6.19%~99.09%,极限荷载值提高了46.04%~135.27%。说明预应力筋材内嵌加固法能够有效改善加固梁的延性和安全性能,刚度也有明显提高,对裂缝的产生和发展都有约束作用,同时螺旋肋钢丝的高强性能也得到了充分发挥。

Abstract: The prestressed near surface mounted helical rib steel wire tension system is adopted, using the process of slotting, reinforcing and tensioning helical rib steel wire, filling glue, and in this paper, an experimental study is conducted on 10 RC beams with prestressed near surface mounted helical rib steel wire. The experimental results indicate that this method could improve the overall performance of the reinforced beams, and first-crack load, flexural load, ultimate load are increased effectively. With the number of helical rib steel wire and prestressed level, first-crack load is increased by 72.6%~321.26%, flexural load is increased by 6.19%-99.09%, ultimate load is increased by 46.04%~135.27%, the effect is obvious. This reinforcing method could effectively improve the ductility, safety performance, the stiffness of reinforced beam, and the emergence and development of cracks could be constrained, and the high strength of helical rib steel wire has been fully play.

关键词:
钢筋混凝土梁;预应力筋材;内嵌加固;承载力
扫二维码用手机看
未找到相应参数组,请于后台属性模板中添加
(1)采用内嵌预应力螺旋肋钢丝加固法,能够很好的改善被加固梁的整体工作性能。本试验中,随加固量及预应力水平不同,被加固梁开裂荷载提高幅度为:72.6%~321.26%,屈服荷载提高幅度为:6.19%~99.09%,极限荷载提高幅度为:46.04%~135.27%,加固效果非常明显。
(2)采用预应力螺旋肋钢丝对混凝土梁进行内嵌抗弯加固,梁的刚度提高明显,对裂缝的产生及其发展均有约束作用,可以延缓加固梁裂缝的发展。
(3)内嵌预应力筋材加固梁跨中截面混凝土应变变化基本符合平截面假定。预应力螺旋肋钢丝延缓了钢筋的应变,能够有效减小梁的变形,且随加固量及初始预应力的增加,加固梁变形减小程度更为显著。
[1] 田水, 谷倩. 碳纤维布预应力补强加固钢筋混凝土受力性能研究[J]. 工业建筑, 2005, 35(6): 88-91. 
[2] 岳清瑞, 李庆伟, 杨勇新. 纤维增强复合材料嵌入式加固技术[J]. 工业建筑, 2004, 34(4): 1-4.
[3] 王天稳, 尹志强. FRP筋NSM加固混凝土构件二次受力时抗弯承载力计算方法[J]. 武汉大学学报: 工学版, 2005, 38(4): 55-58.
[4] El-Hacha R, Rizkalla SH. Near-surface-mounted fiber-rinforced polymer reinforcements for flexural strengthening of concrete structures[J]. ACI structural journal, 2004, 101(5): 717-26.
[5] De Lorenzis L. , Strengthening of RC structures with near surface mounted FRP rods[D]. Ph.D. Thesis, Department of Innovation Engineering, University of Lecce, Lecce, Italy, 2002: 60-68.
[6] 徐有邻. 我国混凝土结构用钢筋的现状及发展[J]. 土木工程学报, 1999, 32(5): 3-9.
[7] 中华人民共和国国家质量监督检验检疫总局. GB/T5223—2002预应力混凝土用钢丝[S]. 北京: 中国标准出版社, 2002.
[8] 曾宪桃. 内嵌螺旋肋钢丝加固混凝土梁抗弯试验研究[R]. 河南焦作, 2007. 
[9] 童谷生, 李志虎, 朱成九, 等. 预应力碳纤维布材加固混凝土梁的受弯性研究[J]. 华东交通大学学报, 2005, 22(2): 1-5.
[10] 李慧敏, 丁亚红. 内嵌预应力螺旋肋钢丝加固混凝土梁受弯性能试验研究[J]. 建筑结构学报, 2013, 34(6): 137-142.
 

相关文件

暂时没有内容信息显示
请先在网站后台添加数据记录。

关注《混凝土与水泥制品》

总访问量 468,401   网站统计

官方微信公众号关闭
苏州混凝土水泥制品研究院有限公司

关于我们    |    联系我们    |    订购杂志    |    回到顶部

版权所有:中国混凝土与水泥制品网  苏ICP备10086386号   网站建设:中企动力 苏州

版权所有:中国混凝土与水泥制品网

苏ICP备10086386号

网站建设:中企动力 苏州