玻化微珠再生保温混凝土配合比优化设计
Optimization Design on Mix Proportion for Glazed Hollow Bead Recycled Aggregate Concrete
2014年第4期
再生混凝土;配合比;优化设计;功效系数法;导热系数
Recycled aggregate concrete; Mix proportion; Optimization design; Efficacy coefficient method; Thermal conductivity
2014年第4期
1000-4637(2014)04-67-04
国家自然科学基金项目(51278073);常州市科技支撑计划项目(CE20135043)
陈春红,朱平华,田 斌
常州大学土木工程系,213164

陈春红,朱平华,田 斌

浏览量:
1000
摘 要:考虑再生混凝土综合性能,选取再生粗、细骨料取代率、水胶比和玻化微珠掺量作为关键影响因素,以抗压强度、抗折强度、保温性能和抗冻性能作为评价指标,设计了再生混凝土配合比正交试验,并运用功效系数法进行了分析。结果表明,水胶比对再生混凝土的抗压强度和抗冻性能影响最大;随着再生粗、细骨料取代率增大,混凝土的力学强度下降;玻化微珠掺量的增加会降低再生混凝土的力学强度,但对其保温性能具有明显的改善作用。通过验证试验发现,只要合理配置,可以配制28d抗压强度达到20MPa、导热系数为0.34 W/(m·K)的玻化微珠再生保温混凝土墙体材料。 Abstract: Considering the performance of recycled aggregate concrete comprehensively, four factors including replacement rates of recycled coarse and fine aggregate, water cement ratio and glazed hollow bead content are selected as key factors, and the compressive strength, flexural strength, thermal conductivity and frost resistance are took as evaluation indices. Orthogonal tests are designed to get the optimal mix proportion, and efficacy coefficient method is used to analyze the test results. The analysis results show that compressive strength and frost resistance of the concrete are most affected by water cement ratio. Mechanical strength of the concrete is deteriorated with increasing the contents of recycled aggregate and glazed hollow bead, but thermal insulation property of the concrete is significantly improved. In addition, the verification test results show that 28d compressive strength of the glazed hollow bead recycled insulation concrete can reach 20MPa, and its insulation resistance can achieve 0.34 W/(m·K) if it’s designed properly.
英文名 : Optimization Design on Mix Proportion for Glazed Hollow Bead Recycled Aggregate Concrete
刊期 : 2014年第4期
关键词 : 再生混凝土;配合比;优化设计;功效系数法;导热系数
Key words : Recycled aggregate concrete; Mix proportion; Optimization design; Efficacy coefficient method; Thermal conductivity
刊期 : 2014年第4期
DOI :
文章编号 : 1000-4637(2014)04-67-04
基金项目 : 国家自然科学基金项目(51278073);常州市科技支撑计划项目(CE20135043)
作者 : 陈春红,朱平华,田 斌
单位 : 常州大学土木工程系,213164

陈春红,朱平华,田 斌

摘要
参数
结论
参考文献
引用本文

摘   要:考虑再生混凝土综合性能,选取再生粗、细骨料取代率、水胶比和玻化微珠掺量作为关键影响因素,以抗压强度、抗折强度、保温性能和抗冻性能作为评价指标,设计了再生混凝土配合比正交试验,并运用功效系数法进行了分析。结果表明,水胶比对再生混凝土的抗压强度和抗冻性能影响最大;随着再生粗、细骨料取代率增大,混凝土的力学强度下降;玻化微珠掺量的增加会降低再生混凝土的力学强度,但对其保温性能具有明显的改善作用。通过验证试验发现,只要合理配置,可以配制28d抗压强度达到20MPa、导热系数为0.34 W/(m·K)的玻化微珠再生保温混凝土墙体材料。

Abstract: Considering the performance of recycled aggregate concrete comprehensively, four factors including replacement rates of recycled coarse and fine aggregate, water cement ratio and glazed hollow bead content are selected as key factors, and the compressive strength, flexural strength, thermal conductivity and frost resistance are took as evaluation indices. Orthogonal tests are designed to get the optimal mix proportion, and efficacy coefficient method is used to analyze the test results. The analysis results show that compressive strength and frost resistance of the concrete are most affected by water cement ratio. Mechanical strength of the concrete is deteriorated with increasing the contents of recycled aggregate and glazed hollow bead, but thermal insulation property of the concrete is significantly improved. In addition, the verification test results show that 28d compressive strength of the glazed hollow bead recycled insulation concrete can reach 20MPa, and its insulation resistance can achieve 0.34 W/(m·K) if it’s designed properly.

关键词:
再生混凝土;配合比;优化设计;功效系数法;导热系数
扫二维码用手机看
未找到相应参数组,请于后台属性模板中添加
(1)再生粗、细骨料取代率的提高会降低混凝土的力学性能,但同时会提高混凝土的保温性能;水胶比增大会降低其抗折强度;玻化微珠掺量的提高能显著地提高保温性能;再生粗、细骨料取代率越低,质量损失率小,抗冻性能越好,水胶比越大其抗冻性能越差。
(2)根据极差和方差分析对配合比进行优化设计,分析得出2种较优的配合比,再通过验证试验得出,再生粗骨料的取代率50%、再生细骨料的取代率30%、水胶比0.4和玻化微珠掺量70%的配合比为最优配合比。
(3)只要配合比适当,玻化微珠再生保温混凝土的抗压强度可以达到20MPa,导热系数可达到0.33W/(m·K),可以作为非承重保温墙体材料使用。
[1] 朱平华,王欣,周军,等. 再生骨料混凝土研究主要进展与发展趋势[J].混凝土,2009(5):90-92,94.
[2] 邓寿昌,张学兵,罗迎社.废弃混凝土再生利用的现状分析与研究展望[J].混凝土,2006(11):20-24. 
[3] 张泽平. 玻化微珠保温混凝土及其结构的基本性能试验与理论分析研究[D].山西:太原理工大学,2009. 
[4] 缪正坤,刘伟,林丽娟,等.建筑垃圾作骨料生产保温砌块的研究[J].新型建筑材料,2010(3):264-267.
[5] 白国良,张锋剑,安昱峄,等.再生混凝土砌块抗压强度和配合比试验研究[J].建筑结构,2012(12):26-29.
[6] 李九苏,肖汉宁,龚建清. 再生骨料水泥混凝土的级配优化试验研究[J].建筑材料学报,2008,11(1):105-110.
[7] Tam,VWY,Tam,CM,Wang,Y.Optimization on proportion for recycled aggregate in concrete using two-stage mixing approach[J].Construction and Building Materials,2007,21(10):1928-1939.
[8] 朱平华,陈华建,郭佳赤,等.大体积混凝土优化设计的四功能准则[J].混凝土,2004(1):41-45.
[9] 张金喜,张建华,邬长森.再生混凝土性能和孔结构的研究[J].建筑材料学报,2006,9(2):142-147. 
[10] Sami W. Tabsh, Akmal S. Abdelfatah. Influence of recycled concrete aggregates on strength properties of concrete[J].Construction and Building Materials , 2009(23):1163-1167.
 