摘 要:运用ABAQUS有限元分析软件对设门洞的加气混凝土砌体芯柱组合墙进行了数值模拟,研究其抗震性能。在有限元模型的计算结果与先前足尺试件的试验结果进行了对比验证的基础上,研究了竖向正压力、洞口设置的大小及位置三因素对墙体抗震性能的影响。研究表明:随竖向压应力的增加,墙体的抗震性能得到改善;但竖向压应力对极限荷载的影响小于对极限荷载下位移的影响;门洞宽度增大时,墙体的极限承载力降低,降低程度与墙体截面积的削弱程度基本成比例;门洞位置的改变,对墙体抗震性能的影响较小。 Abstract: In order to study the seismic performance of aerated concrete block masonry composite wall with a door opening,numerical simulation was conducted by using finite element software ABAQUS. The finite element results were verified with the laboratory results of full-scale specimens. On this basis, the composite walls with different parameters were investigated, which includes their vertical compression stress, opening sizes and opening position. The results show that with the increasing of vertical compression stress,the seismic performance improve;however, the effect of the vertical compression stress on the ultimate load is less than that on the displacement under ultimate load;With the increasing of the door width, the decrease in the wall’s bearing capacity is proportional to the decrease in the wall’s net area; and the change of door’s position has less effect on seismic performance of the composite wall.
英文名 : Analysis on Seismic Behavior of Aerated Concrete Masonry Composite Wall with Core Columns and a Door Opening
刊期 : 2013年第10期
关键词 : 加气混凝土;组合墙;抗震性能;数值模拟
Key words : Aerated concrete; Composite wall; Seismic behavior; Numerical simulation
刊期 : 2013年第10期
DOI :
文章编号 : 1000-4637(2013)10-62-04
基金项目 : 河北省自然基金项目(E2012403012);河北省教育厅青年基金项目(Q2012146);校内青年科学研究基金项目(XN201204)
作者 : 吴会阁1,赵 彦2,曹秀玲1,谌会芹1
单位 : 1. 石家庄经济学院勘查技术与工程学院,050031; 2. 防灾科技学院,三河 065201

吴会阁1,赵 彦2,曹秀玲1,谌会芹1

摘要
参数
结论
参考文献
引用本文

摘   要:运用ABAQUS有限元分析软件对设门洞的加气混凝土砌体芯柱组合墙进行了数值模拟,研究其抗震性能。在有限元模型的计算结果与先前足尺试件的试验结果进行了对比验证的基础上,研究了竖向正压力、洞口设置的大小及位置三因素对墙体抗震性能的影响。研究表明:随竖向压应力的增加,墙体的抗震性能得到改善;但竖向压应力对极限荷载的影响小于对极限荷载下位移的影响;门洞宽度增大时,墙体的极限承载力降低,降低程度与墙体截面积的削弱程度基本成比例;门洞位置的改变,对墙体抗震性能的影响较小。

Abstract: In order to study the seismic performance of aerated concrete block masonry composite wall with a door opening,numerical simulation was conducted by using finite element software ABAQUS. The finite element results were verified with the laboratory results of full-scale specimens. On this basis, the composite walls with different parameters were investigated, which includes their vertical compression stress, opening sizes and opening position. The results show that with the increasing of vertical compression stress,the seismic performance improve;however, the effect of the vertical compression stress on the ultimate load is less than that on the displacement under ultimate load;With the increasing of the door width, the decrease in the wall’s bearing capacity is proportional to the decrease in the wall’s net area; and the change of door’s position has less effect on seismic performance of the composite wall.

关键词:
加气混凝土;组合墙;抗震性能;数值模拟
扫二维码用手机看
未找到相应参数组,请于后台属性模板中添加
(1)当竖向压应力的增大时,门洞墙体的承载力得到提高,出现极限荷载时所对应的极限位移也有所增加;竖向压应力对门洞墙体极限荷载的影响程度小于对极限荷载下对应位移的影响。
(2)当门洞宽度增大时,极限承载力的降低程度比到达极限承载力时的相应位移的降低程度大一些,且极限承载力的降低程度与墙体截面积的削弱程度基本成比例。
(3)相同门洞宽度下,中洞墙体与偏洞墙体的极限荷载、最终荷载都比较接近。
[1] 高连玉.加气混凝土砌块承重多层房屋的关键技术[J].砖瓦世界,2007(1):43-46.
[2] 于敬海,苏志德,田淑明,等. 蒸压砂加气混凝土承重墙抗震性能研究[J].低温建筑技术,2007(4):38-40.
[3] 赵成文,张亮,高连玉,等. A类蒸压加气混凝土砌块墙体抗震性能试验[J].沈阳建筑大学学报,2009(3):426-432.
[4] 谢峰,于敬海,陈晓祥. 承重开洞墙体抗震性能的有限元分析[J]. 低温建筑技术,2009(8):72-74.
[5] 赵全斌. 改善蒸压加气混凝土承重墙体抗震性能试验研究[D]. 天津:天津大学,2006.
[6] 凌沛春.蒸压加气混凝土砌块组合墙体的抗震性能试验研究[D].北京:北京工业大学 2011.
[7] 吴会阁.设芯柱的蒸压加气混凝土砌块砌体承重墙抗震性能的研究[D]. 北京:北京工业大学,2011.
[8] 吴会阁,赵均,凌沛春,等.设芯柱的蒸压加气混凝土砌体承重墙抗震性能试验研究[J]. 北京工业大学学报,2013(1):51-56.
[9] Finite element analysis of vertical stress's effect on seismic performance of autoclaved aerated concrete block masonry walls[J]. Advances in civil Engineering and Architecture  Innovation,2011(2):1010-1013.
[10] 吴会阁,赵均.带窗洞的加气混凝土砌块砌体墙抗震性能分析[J].世界地震工程,2012(1):33-38.
[11] 夏祖宏,顾同曾,周炳章,等. 采用加气混凝土制品建造新农村住宅的研究[J].墙材革新与建筑节能,2010(7):23-25.
[12] 石亦平,周玉蓉.ABAQUS有限元分析实例详解[M].北京:机械工业出版社, 2006.
[13] 王玉镯,傅传国. ABAQUS结构工程分析及实例详解[M].北京:中国建筑工业出版社,2010.
 

相关文件

暂时没有内容信息显示
请先在网站后台添加数据记录。

关注《混凝土与水泥制品》

总访问量 468,401   网站统计

官方微信公众号关闭
苏州混凝土水泥制品研究院有限公司

关于我们    |    联系我们    |    订购杂志    |    回到顶部

版权所有:中国混凝土与水泥制品网  苏ICP备10086386号   网站建设:中企动力 苏州

版权所有:中国混凝土与水泥制品网

苏ICP备10086386号

网站建设:中企动力 苏州