四边简支预制混凝土无机保温夹心墙体静力性能试验研究
Static Behaviors Test Research on Precast Concrete Inorganic Insulation Sandwich Composite Wall Panel with Four Sides
2013年第8期
预制混凝土;抗弯性能;承载能力;荷载-滑移关系
Precast concrete; Flexural behavior; Bearing capacity; Load-slip relations
2013年第8期
1000-4637(2013)08-58-04
国家“十二五”科技支撑计划项目(2010BAK69 B28),上海市科学技术委员会科研计划项目(10dz0583700)
朱永明1,杨佳林2,薛伟辰2
1.上海城建物资有限公司,200063; 2.同济大学建筑工程系,上海 200092

朱永明1,杨佳林2,薛伟辰2

浏览量:
1000
摘 要:以上海市某工程为例,开展了四边简支足尺预制混凝土无机保温夹心墙体的平面外堆载试验,对墙体的承载能力、荷载?滑移关系、墙体变形以及墙体连接件与墙体滑移等进行了研究。研究表明:墙体的开裂荷载为208kN,是荷载设计值的7.4倍;设计荷载作用下墙体的跨中挠度为1.16mm。墙体的抗弯刚度大,抗裂度与承载力高,并具有较大的安全储备。 Abstract: In order to investigate the flexural behavior of pre-cast concrete inorganic insulation sandwich composite wall panel, a full-scale specimen simply supported on four sides was got from a practical project in Shanghai and a out-of-plane heaped load test of the specimen was carried out. Meanwhile, the bearing capacity, deformation and slip between FRP connector and concrete panel were studied in detail. The results show that the cracking load of the wall panel is 208kN, which is about 7.4 times of the design load. Mid-span deflection of the wall panel is 1.16mm under the action of the design load. It can be concluded that the wall panel has large flexural rigidity and load capacity,and its property can completely meet the normal serviceability requirements.
英文名 : Static Behaviors Test Research on Precast Concrete Inorganic Insulation Sandwich Composite Wall Panel with Four Sides
刊期 : 2013年第8期
关键词 : 预制混凝土;抗弯性能;承载能力;荷载-滑移关系
Key words : Precast concrete; Flexural behavior; Bearing capacity; Load-slip relations
刊期 : 2013年第8期
DOI :
文章编号 : 1000-4637(2013)08-58-04
基金项目 : 国家“十二五”科技支撑计划项目(2010BAK69 B28),上海市科学技术委员会科研计划项目(10dz0583700)
作者 : 朱永明1,杨佳林2,薛伟辰2
单位 : 1.上海城建物资有限公司,200063; 2.同济大学建筑工程系,上海 200092

朱永明1,杨佳林2,薛伟辰2

摘要
参数
结论
参考文献
引用本文

摘   要:以上海市某工程为例,开展了四边简支足尺预制混凝土无机保温夹心墙体的平面外堆载试验,对墙体的承载能力、荷载?滑移关系、墙体变形以及墙体连接件与墙体滑移等进行了研究。研究表明:墙体的开裂荷载为208kN,是荷载设计值的7.4倍;设计荷载作用下墙体的跨中挠度为1.16mm。墙体的抗弯刚度大,抗裂度与承载力高,并具有较大的安全储备。

Abstract: In order to investigate the flexural behavior of pre-cast concrete inorganic insulation sandwich composite wall panel, a full-scale specimen simply supported on four sides was got from a practical project in Shanghai and a out-of-plane heaped load test of the specimen was carried out. Meanwhile, the bearing capacity, deformation and slip between FRP connector and concrete panel were studied in detail. The results show that the cracking load of the wall panel is 208kN, which is about 7.4 times of the design load. Mid-span deflection of the wall panel is 1.16mm under the action of the design load. It can be concluded that the wall panel has large flexural rigidity and load capacity,and its property can completely meet the normal serviceability requirements.

关键词:
预制混凝土;抗弯性能;承载能力;荷载-滑移关系
扫二维码用手机看
未找到相应参数组,请于后台属性模板中添加
(1)在最大荷载作用下,墙体裂缝宽度0.52mm,跨中挠度为28mm。在整个加载过程中,混凝土板与保温层之间无明显的错动现象,连接件与上、下层钢筋混凝土板的滑移均较小,最大荷载时的滑移值小于0.4mm,连接件表面也未见损伤,这表明连接件具有较大的抗剪承载力与抗剪刚度。
(2)在加载过程中,混凝土应变与钢筋应变较小,且应变量基本随荷载的增加呈线性增长,此时墙体处于弹性阶段。
(3) FRP 连接件三个方向的应变值均较小, 最大应变小于3000με,大大低于材料FRP材料的极限应变值。
(4)实测墙体开裂荷载为208kN,是设计值的7.4倍,表明墙体在正常使用极限状态下具有较高的抗裂性。
(5)墙体在平面外设计荷载(28kN)作用下的挠度值约为1.16mm,小于规范规定挠度限值14mm(L/200=14mm),满足正常使用要求。
 
[1] ANON. Selection and use of materials for precast concrete wall panels. ACI Structural Journal, 1969, 66 (10): 814-820.
[2] 张同亿, 张兴虎, 吴敏哲. 带框架复合墙抗震性能试验研究[J]. 安建筑科技大学学报, 2000, 32(3): 209-212.
[3] 顾志建, 顾鹏. 从上海11.15特大火灾谈高层建筑设计规范的缺陷[J]. 建筑, 2011,(5): 12-14.
[4] 杨峻平, 朱敬华. 对央视新址北配楼火灾的思考[J]. 武警学院学报, 2009, 25(8): 73-76.
[5] 洪雯, 施美灵. 建筑节能——绿色建筑对亚洲未来发展的重要性[M]. 北京: 中国大百科全书出版社, 2008. 
[6] 薛伟辰, 杨佳林, 王君若. 预制夹芯保温墙体FRP连接件抗拔性能试验研究[J]. 玻璃钢/复合材料, 2012(4): 55-58.
[7] 杨佳林, 秦珩, 刘国权, 等. 板式纤维塑料连接件力学性能试验研究[J]. 塑料工业, 2012,40(8): 69-72.

相关文件

暂时没有内容信息显示
请先在网站后台添加数据记录。

关注《混凝土与水泥制品》

总访问量 468,401   网站统计

官方微信公众号关闭
苏州混凝土水泥制品研究院有限公司

关于我们    |    联系我们    |    订购杂志    |    回到顶部

版权所有:中国混凝土与水泥制品网  苏ICP备10086386号   网站建设:中企动力 苏州

版权所有:中国混凝土与水泥制品网

苏ICP备10086386号

网站建设:中企动力 苏州