超低能耗保温夹芯墙板金属夹形拉结件受力性能分析
Analysis on Mechanical Performance of Metal Clamp Connectors on Precast Concrete Sandwich Wall with Ultra-low Energy Consumption
2020年第5期
预制混凝土夹芯保温墙;力学性能;拉结件;安全系数
Precast concrete sandwich wall; Mechanical property; Connector; Safety factor
2020年第5期
10.19761/j.1000-4637.2020.05.061.06
国家重点研发计划项目(2017YFC0703703)。
吕安安1,张绍武1,赵志刚2,周 剑3
1.沈阳建筑大学 土木工程学院,110168;2.北京市燕通建筑构件有限公司,102202;3.建研科技股份有限公司,北京 100013

吕安安1,张绍武1,赵志刚2,周 剑3

吕安安,张绍武,赵志刚,等.超低能耗保温夹芯墙板金属夹形拉结件受力性能分[J].混凝土与水泥制品,2020(5):61-65,91.

LYU A A,ZHANG S W,ZHAO Z G,et al.Analysis on Mechanical Performance of Metal Clamp Connectors on Precast Concrete Sandwich Wall with Ultra-low Energy Consumption[J].China Concrete and Cement Products,2020(5):61-65,91.

浏览量:
1000
摘 要:为了探讨超低能耗夹芯保温外墙拉结件受力性能,分别从抗拉性能、抗剪性能、拉剪性能和对应的变形性能进行了试验研究,验证了数值模拟分析的可行性,并根据试验和模拟结果给出了拉结件的安全系数。结果表明,夹形拉结件的抗拉性能、拉剪性能的抗拉性能可以满足国内标准的可靠性要求;但抗剪性能难以满足国内标准要求;拉结件在试验中达到设计承载力时变形量均小于胶缝变形能力2.54mm,不影响接缝性能。Abstract:Inordertodiscussthemechanicalpropertiesoftheconnectorsofthesandwichinsulationwallwithultra-lowenergyconsumption,thetensileproperties,shearproperties,tensileshearpropertiesandcorrespondingdeformationpropertieswerestudied,andthefeasibilityofnumericalsimulationanalysiswasverified,andthesafetyfactorofthemetalconnectorswasgivenaccordingtothetestandsimulationresults.Theresultsshowthatthetensilepropertiesandtensileshearpropertiesoftheconnectorscanmeetthereliabilityrequirementsofdomesticstandards,however,theshearperformanceisdifficulttomeetrequirementsofthedomesticstandards.Whentheconnectorsreachthedesignbearingcapacityinthetest,thedeformationamountislessthan2.54mmoftheplasticjointdeformationcapacity,whichdoesnotaffectthejointperformance.
英文名 : Analysis on Mechanical Performance of Metal Clamp Connectors on Precast Concrete Sandwich Wall with Ultra-low Energy Consumption
刊期 : 2020年第5期
关键词 : 预制混凝土夹芯保温墙;力学性能;拉结件;安全系数
Key words : Precast concrete sandwich wall; Mechanical property; Connector; Safety factor
刊期 : 2020年第5期
DOI : 10.19761/j.1000-4637.2020.05.061.06
文章编号 :
基金项目 : 国家重点研发计划项目(2017YFC0703703)。
作者 : 吕安安1,张绍武1,赵志刚2,周 剑3
单位 : 1.沈阳建筑大学 土木工程学院,110168;2.北京市燕通建筑构件有限公司,102202;3.建研科技股份有限公司,北京 100013

吕安安1,张绍武1,赵志刚2,周 剑3

吕安安,张绍武,赵志刚,等.超低能耗保温夹芯墙板金属夹形拉结件受力性能分[J].混凝土与水泥制品,2020(5):61-65,91.

LYU A A,ZHANG S W,ZHAO Z G,et al.Analysis on Mechanical Performance of Metal Clamp Connectors on Precast Concrete Sandwich Wall with Ultra-low Energy Consumption[J].China Concrete and Cement Products,2020(5):61-65,91.

摘要
参数
结论
参考文献
引用本文

摘  要:为了探讨超低能耗夹芯保温外墙拉结件受力性能,分别从抗拉性能、抗剪性能、拉剪性能和对应的变形性能进行了试验研究,验证了数值模拟分析的可行性,并根据试验和模拟结果给出了拉结件的安全系数。结果表明,夹形拉结件的抗拉性能、拉剪性能的抗拉性能可以满足国内标准的可靠性要求;但抗剪性能难以满足国内标准要求;拉结件在试验中达到设计承载力时变形量均小于胶缝变形能力2.54 mm,不影响接缝性能。

Abstract: In order to discuss the mechanical properties of the connectors of the sandwich insulation wall with ultra-low energy consumption, the tensile properties, shear properties, tensile shear properties and corresponding deformation properties were studied, and the feasibility of numerical simulation analysis was verified, and the safety factor of the metal connectors was given according to the test and simulation results. The results show that the tensile properties and tensile shear properties of the connectors can meet the reliability requirements of domestic standards, however, the shear performance is difficult to meet requirements of the domestic standards. When the connectors reach the design bearing capacity in the test, the deformation amount is less than 2.54 mm of the plastic joint deformation capacity, which does not affect the joint performance.

关键词:
分析
the
性能
of
properties
and
connectors
tensile
shear
deformation
扫二维码用手机看
未找到相应参数组,请于后台属性模板中添加
(1)该夹形金属连接件的抗拉承载力、拉剪承载力满足国内设计时的规范要求,但拉结件的抗剪承载力难以满足国内标准拟定的安全系数要求。
(2)在不考虑保温板贡献的假定下,建议对此类拉结件的设计受剪承载力按安全系数要求进行折减或直接基于承载力标准值及拟定安全系数设计;达到设计承载力时变形均小于接缝变形能力,不影响接缝性能。
[1] 余彦洲.现行节能标准下居住建筑节能相关问题的研究[D].武汉:武汉科技大学,2015.
[2] STONE.Research on building energy efficiency development in China[J].Chinese and foreign e-ntrepreneurs,2014(3):179-181.
[3] 张欣苗.被动式超低能耗建筑在国内寒冷地区的设计现状[J].绿色环保建材,2019,147(5):75.
[4] 苏永波,单贺明,侯纲.被动式超低能耗建筑外墙保温系统施工措施分析[J].混凝土与水泥制品,2019(5):84-86.
[5] 朱文祥,吴志敏,张海遐,等.预制夹芯保温墙体连接件的研究现状[J].建筑节能,2017,45(4):48-51.
[6] 丛茂林,田春雨,李智斌,等.预制夹心保温墙体中拉结件设计方法[J].建筑科学,2018,34(1):8-13.
[7] WOLTMAN,TOMLINSON G D,FAM A.Investigation of Various GFRP Shear Connectors for Insulated Precast Conrete Sandwich Wall Panels[J].Journal of Composites for Construction,2013,17(5):711-721.
[8] 刘若南.基于强度的预制混凝土夹芯保温墙板连接件设计研究[D].武汉:武汉理工大学,2014.
[9] NAITO,HOEMANN C J,BEACRAFT M,et al.Performance and Characterization of Shear Ties for Use in Insulated Precast Concrete Sandwich Wall Panels[J].Journal of Structural Engineering,2012,138(1):52-61.
[10] 张延年,李恒,刘明.新型夹心墙用耐腐蚀拉结件受力性能试验[J].沈阳工业大学学报,2010,32(2):228-234.
[11] 孟宪宏,周阿龙,刘海成.预制保温外墙板连接件力学性能试验[J].沈阳建筑大学学报,2014,30(2):232-233.
[12] 申亚楠.预制夹芯保温复合墙板的研制及适用性评价[D]. 徐州:中国矿业大学,2018.
[13] 刘卉.预制混凝土夹芯保温外挂墙板研究[D].南京:东南大学,2016.
[14] 彭军.装配式钢结构住宅关键技术研究与工程实践[D].合肥:合肥工业大学,2017.
[15] 中华人民共和国住房和城乡建设部.GB 50010—2016混凝土结构设计规范[S].北京:中国建筑工业出版社,2016.
[16] 中华人民共和国住房和城乡建设部.JGJ 145—2013混凝土结构后锚固技术规程[S].北京:中国建筑工业出版社,2013.
[17] PCI Industry Handbook Committee.MNL 120-40PCI Design Handbook:Precast and Prestressed Concrete[M].Sixth Edition.Chicago:Precast and Prestressed Concrete Institute,2004. 

吕安安,张绍武,赵志刚,.超低能耗保温夹芯墙板金属夹形拉结件受力性能分[J].混凝土与水泥制品,2020(5):61-65,91.

LYU A A,ZHANG S W,ZHAO Z G,et al.Analysis on Mechanical Performance of Metal Clamp Connectors on Precast Concrete Sandwich Wall with Ultra-low Energy Consumption[J].China Concrete and Cement Products,2020(5):61-65,91.

 

相关文件

暂时没有内容信息显示
请先在网站后台添加数据记录。

关注《混凝土与水泥制品》

总访问量 468,401   网站统计

官方微信公众号关闭
苏州混凝土水泥制品研究院有限公司

关于我们    |    联系我们    |    订购杂志    |    回到顶部

版权所有:中国混凝土与水泥制品网  苏ICP备10086386号   网站建设:中企动力 苏州

版权所有:中国混凝土与水泥制品网

苏ICP备10086386号

网站建设:中企动力 苏州