不同应力比下玄武岩纤维水泥基复合材料抗氯离子渗透性研究
Study on the Resistance to Chloride Ion Permeability of Basalt Fiber Cement Composites under Different Stress Ratios
2020年第4期
玄武岩纤维水泥基复合材料;抗氯离子渗透性;电通量试验;应力比
BFCC; Resistance to chloride ion permeability; Electric flux test; Stress ratio
2020年第4期
10.19761/j.1000-4637.2020.04.046.04
国家自然科学基金项目(11762015、11362013);内蒙古工业大学科学研究项目(ZD201712)。
何晓雁,张智鑫,张淑艳,包媛媛,张改芬
内蒙古工业大学土木工程学院,呼和浩特 010051

何晓雁,张智鑫,张淑艳,包媛媛,张改芬

何晓雁,张智鑫,张淑艳,等.不同应力比下玄武岩纤维水泥基复合材料抗氯离子渗透性研究[J].混凝土与水泥制品,2020(4):46-48,53.

HE X Y,ZHANG Z X,ZHANG S Y,et al.Study on the Resistance to Chloride Ion Permeability of Basalt Fiber Cement Composites under Different Stress Ratios[J].China Concrete and Cement Products,2020(4):46-48,53.

浏览量:
1000
摘 要:通过循环加载压缩及电通量试验,研究了玄武岩纤维长度、养护龄期和循环加载压缩试验应力比对玄武岩纤维水泥基复合材料(BFCC)抗氯离子渗透性的影响。结果表明,随着养护龄期的增加,BFCC的6h电通量值逐渐减小;随着玄武岩纤维长度的增加,BFCC的6h电通量呈降低趋势,但是,当纤维长度从12mm增加到20mm时,BFCC的6h电通量降低速率减小;随着应力比的增加,BFCC的6h电通量呈先降低后增加的趋势,且应力比为0.2,BFCC的6h电通量值最小。Abstract:Basedonthecyclicloadingcompressionandelectricalfluxtests,theeffectsofthelengthofbasaltfiber,curingageandthestressratioofcyclicloadingcompressiontestontheresistancetochlorideionpermeabilityofbasaltfibercementcomposites(BFCC)werestudied.Theresultsshowthatwiththeincreaseofcuringage,the6helectricfluxvalueofBFCCgraduallydecreases.Whenthelengthofbasaltfiberincreases,the6helectricfluxofBFCCdecreases,however,whenthelengthofbasaltfiberincreasesfrom12mmto20mm,thedecreaserateof6helectricfluxofBFCCdecreases.Whenthestressratioincreases,the6helectricfluxofBFCCdecreasesfirstandthenincreases,andwhenthestressratiois0.2,the6helectricfluxofBFCCisthesmallest.
英文名 : Study on the Resistance to Chloride Ion Permeability of Basalt Fiber Cement Composites under Different Stress Ratios
刊期 : 2020年第4期
关键词 : 玄武岩纤维水泥基复合材料;抗氯离子渗透性;电通量试验;应力比
Key words : BFCC; Resistance to chloride ion permeability; Electric flux test; Stress ratio
刊期 : 2020年第4期
DOI : 10.19761/j.1000-4637.2020.04.046.04
文章编号 :
基金项目 : 国家自然科学基金项目(11762015、11362013);内蒙古工业大学科学研究项目(ZD201712)。
作者 : 何晓雁,张智鑫,张淑艳,包媛媛,张改芬
单位 : 内蒙古工业大学土木工程学院,呼和浩特 010051

何晓雁,张智鑫,张淑艳,包媛媛,张改芬

何晓雁,张智鑫,张淑艳,等.不同应力比下玄武岩纤维水泥基复合材料抗氯离子渗透性研究[J].混凝土与水泥制品,2020(4):46-48,53.

HE X Y,ZHANG Z X,ZHANG S Y,et al.Study on the Resistance to Chloride Ion Permeability of Basalt Fiber Cement Composites under Different Stress Ratios[J].China Concrete and Cement Products,2020(4):46-48,53.

摘要
参数
结论
参考文献
引用本文

摘  要:通过循环加载压缩及电通量试验,研究了玄武岩纤维长度、养护龄期和循环加载压缩试验应力比对玄武岩纤维水泥基复合材料(BFCC)抗氯离子渗透性的影响。结果表明,随着养护龄期的增加,BFCC的6 h电通量值逐渐减小;随着玄武岩纤维长度的增加,BFCC的6 h电通量呈降低趋势,但是,当纤维长度从12 mm增加到20 mm时,BFCC的6 h电通量降低速率减小;随着应力比的增加,BFCC的6 h电通量呈先降低后增加的趋势,且应力比为0.2,BFCC的6 h电通量值最小。

Abstract: Based on the cyclic loading compression and electrical flux tests, the effects of the length of basalt fiber, curing age and the stress ratio of cyclic loading compression test on the resistance to chloride ion permeability of basalt fiber cement composites(BFCC) were studied. The results show that with the increase of curing age, the 6 h electric flux value of BFCC gradually decreases. When the length of basalt fiber increases, the 6 h electric flux of BFCC decreases, however, when the length of basalt fiber increases from 12 mm to 20 mm, the decrease rate of 6 h electric flux of BFCC decreases. When the stress ratio increases, the 6 h electric flux of BFCC decreases first and then increases, and when the stress ratio is 0.2, the 6 h electric flux of BFCC is the smallest.

关键词:
玄武岩纤维水泥基复合材料;抗氯离子渗透性;电通量试验;应力比
扫二维码用手机看
未找到相应参数组,请于后台属性模板中添加
(1)在BF长度相同的情况下,当养护龄期由28 d增长到112 d时,BFCC的电通量值逐渐减小,且112 d时BFCC抗氯离子渗透性能最好。
(2)随着BF长度增加,112 d养护龄期时BFCC 的电通量呈降低趋势,但当纤维长度从12 mm增加到20 mm时,BFCC的电通量降低速率减小。
(3)BFCC的电通量随应力比增加呈先减小后增大的趋势,且应力比为0.2时,BFCC的电通量值最小,抗氯离子渗透性能较好。
[1] 金建东.玄武岩纤维增强混凝土抗氯离子渗透性能试验研究[D].哈尔滨:哈尔滨工程大学,2017.
[2] 刘浩喆.玄武岩-聚丙烯混杂纤维混凝土抗氯离子渗透性能试验研究[D].哈尔滨:哈尔滨工程大学,2017.
[3] 刘华挺,张俊芝,傅招旗,等.短切玄武岩纤维混凝土构件抗氯盐侵蚀试验[J].混凝土,2011(1):14-15.
[4] 何军拥,田承宇.玄武岩纤维水工高性能混凝土的耐久性研究[J].混凝土与水泥制品,2013(5):46-48.
[5] 范云廷.玄武岩纤维RPC基本力学性能及耐久性研究[D].吉林:东北电力大学,2017.
[6] KIRTHIKA S K,SINGH S K,SURYA M S.Durability studies on basalt fibre reinforced concrete[J]Indian Concrete Journal,2018,4:45-55.
[7] NIU D T,HUANG D G,FU Q.Experimental investigation on compressive strength and chloride permeability of fiber-reinforced concrete with basalt-polypropylene fibers[J].Advances in Structural Engineering,2019,10:2278-2288.
[8] 中华人民共和国住房和城乡建设部.GB/T 50082—2009普通混凝土长期性能和耐久性能试验方法标准[S].北京:中国建筑工业出版社,2009.
[9] 薛明凯.玄武岩与聚丙烯双掺纤维混凝土力学性能研究[D].淮南:安徽理工大学,2018.
[10] 林毓梅.混凝土的结构与变形[Z].河海大学研究生讲义,1988.

何晓雁,张智鑫,张淑艳,.不同应力比下玄武岩纤维水泥基复合材料抗氯离子渗透性研究[J].混凝土与水泥制品,2020(4):46-48,53.

HE X Y,ZHANG Z X,ZHANG S Y,et al.Study on the Resistance to Chloride Ion Permeability of Basalt Fiber Cement Composites under Different Stress Ratios[J].China Concrete and Cement Products,2020(4):46-48,53.