摘 要:混凝土浇筑宜连续不间断进行,以避免出现削弱结构受力性能及变形特征的施工缝。传统的施工缝位置一般留于“剪力较小且便于施工”之部位,此法存在一些缺陷和不足。针对这种情况,提出了“受力较小且便于施工”的施工缝位置留置原则。 Abstract: Pouring concrete should be carried out without intermittence, so as to prevent the construction joints which may weaken the structure bearing performances and have deformation characteristic. The traditional construction joints are usually marked on the position with “smaller shearing and convenient for construction”, however, this method has a few defects and shortcoming. Aiming at this situation, the setting principle of the construction joints position with “smaller loading and convenient for construction” is proposed
英文名 : Discussion on the Construction Joints Position of Concrete
刊期 : 2011年第7期
关键词 : 施工缝;施工缝界面;剪力较小;受力较小
Key words : Construction joint; Interface of construction joint; Smaller Shearing; Smaller Loading
刊期 : 2011年第7期
DOI :
文章编号 : 1000-4637(2011)07-61-04
基金项目 :
作者 : 邱玉深
单位 : 辽宁省铁岭市第一建筑工程公司,112000

邱玉深

摘要
参数
结论
参考文献
引用本文

摘   要:混凝土浇筑宜连续不间断进行,以避免出现削弱结构受力性能及变形特征的施工缝。传统的施工缝位置一般留于“剪力较小且便于施工”之部位,此法存在一些缺陷和不足。针对这种情况,提出了“受力较小且便于施工”的施工缝位置留置原则。

Abstract: Pouring concrete should be carried out without intermittence, so as to prevent the construction joints which may weaken the structure bearing performances and have deformation characteristic. The traditional construction joints are usually marked on the position with “smaller shearing and convenient for construction”, however, this method has a few defects and shortcoming. Aiming at this situation, the setting principle of the construction joints position with “smaller loading and convenient for construction” is proposed

关键词:
施工缝;施工缝界面;剪力较小;受力较小
扫二维码用手机看
未找到相应参数组,请于后台属性模板中添加

综上所述,施工缝宜留置于结构受力较小且便于施工部位,受力较小与便于施工不可偏顾一方。当两者互相矛盾,即遇到受力较小而不便施工或受力较大而便于施工时,处理原则应是统筹兼顾、均衡利弊、综合分析。受力较小与便于施工两者之间无主次、先后之分,不能只顾受力较小而不顾便于施工,也不能只顾便于施工而不顾受力较小。受力较小而不便施工的施工缝,由于施工缝混凝土浇筑及施工缝处理不便操作,可能导致施工缝界面抗力损失加大。受力较大但便于施工的施工缝,由于施工缝混凝土浇筑及施工缝处理便于操作,可能使施工缝界面抗力增加。同时应认识到的是,无论如何留施工缝,施工缝界面都会损伤和削弱混凝土截面的抗力和刚度,所以,应尽量少留置施工缝。