电热砂浆板制作低温辐射地面的试验研究
Experimental Study on Manufacturing of Low-temperature Radiating Floor by Using o Electro-heating Mortar Plates
2007年第2期
炭黑水泥砂浆;电采暖;电阻率;热辐射地面
Cement-carbon mortar; Electro-suppluing the heat; Electric resistance rate; Heat radiating floor
2007年第2期
1000-4637(2007)02-01-03
孙明清, 王小英,穆新盈,侯作富,李卓球
武汉理工大学理学院工程结构与力学系,430070

孙明清, 王小英,穆新盈,侯作富,李卓球

浏览量:
1000
摘 要:用自制的炭黑水泥砂浆板制作室内地面并以此进行了低温辐射采暖的试验研究。介绍了炭黑水泥砂浆板在室内的排布、接线、温度测点的布置,给出了在恒定电压下室内空气温度、加热板温度、隔热层温度等随通电时间变化的试验结果,研究了电流变化的规律以及多次电热试验后加热板电阻的稳定性。实验表明,炭黑水泥砂浆板通电后产生的热量完全可满足室内采暖的需要,室内的温度分布均匀,且地板能蓄热因而有利于维持室内环境的热稳定。在通电过程中以及在多次通断电时,电阻基本稳定,电热功率稳定。 Abstract: An interior floor is developed by using of author's cement-carbon mortar plates and the tests on thermal radiation of it are carried out. Here, the distribution of plates, the linking scheme for each plates and the position of thermal-measuring points are introduced; the test rezults on relationship between electro-passed time and temperature, where including at different places of room, on top of heating plate and under insulated plates, are reported; the stability of electric current and resistance, after many times of switch on or off, is experimentally researched. The tests show that, for the quantity of heat that produced by cement-carbon mortar plates, it is able to completely meet the demands for supplying heat, and the temperature distribution in room is even. As the plates can store heat, so that is profitable to keeping the room temperature for unchanging. During the electricity is in turn on and after many times of switch off or on, the electric resistance and power are keep stable.
英文名 : Experimental Study on Manufacturing of Low-temperature Radiating Floor by Using o Electro-heating Mortar Plates
刊期 : 2007年第2期
关键词 : 炭黑水泥砂浆;电采暖;电阻率;热辐射地面
Key words : Cement-carbon mortar; Electro-suppluing the heat; Electric resistance rate; Heat radiating floor
刊期 : 2007年第2期
DOI :
文章编号 : 1000-4637(2007)02-01-03
基金项目 :
作者 : 孙明清, 王小英,穆新盈,侯作富,李卓球
单位 : 武汉理工大学理学院工程结构与力学系,430070

孙明清, 王小英,穆新盈,侯作富,李卓球

摘要
参数
结论
参考文献
引用本文

摘   要:用自制的炭黑水泥砂浆板制作室内地面并以此进行了低温辐射采暖的试验研究。介绍了炭黑水泥砂浆板在室内的排布、接线、温度测点的布置,给出了在恒定电压下室内空气温度、加热板温度、隔热层温度等随通电时间变化的试验结果,研究了电流变化的规律以及多次电热试验后加热板电阻的稳定性。实验表明,炭黑水泥砂浆板通电后产生的热量完全可满足室内采暖的需要,室内的温度分布均匀,且地板能蓄热因而有利于维持室内环境的热稳定。在通电过程中以及在多次通断电时,电阻基本稳定,电热功率稳定。

Abstract: An interior floor is developed by using of author's cement-carbon mortar plates and the tests on thermal radiation of it are carried out. Here, the distribution of plates, the linking scheme for each plates and the position of thermal-measuring points are introduced; the test rezults on relationship between electro-passed time and temperature, where including at different places of room, on top of heating plate and under insulated plates, are reported; the stability of electric current and resistance, after many times of switch on or off, is experimentally researched. The tests show that, for the quantity of heat that produced by cement-carbon mortar plates, it is able to completely meet the demands for supplying heat, and the temperature distribution in room is even. As the plates can store heat, so that is profitable to keeping the room temperature for unchanging. During the electricity is in turn on and after many times of switch off or on, the electric resistance and power are keep stable.

关键词:
炭黑水泥砂浆;电采暖;电阻率;热辐射地面
扫二维码用手机看
未找到相应参数组,请于后台属性模板中添加
(1)炭黑水泥砂浆板用作电热辐射地面能实现室内取暖功能;
(2)炭黑水泥砂浆板用于室内采暖时,室内气温比较均匀,且地板能蓄热,有利于维持室内环境的热稳定;
(3)炭黑水泥砂浆板在通电过程中以及在多次通断电时,电阻基本稳定,电热功率稳定。
[1] 王小英,孙明清,等. 纳米炭黑水泥砂浆的导电性与电热特性研究.功能材料,2006.
[2] 李仁福,戴成琴,于纪寿,惰成飞.导电混凝土采暖地面. 混凝土, 1998,(1): 47-48.
[3] P. Xie, J. J. Beaudoin. Electrically Conductive Concrete and Its Application in Deicing. Advances in Concrete Technology, Proceedings, Second CANMET/ACI International Symposium, SP-154, American Concrete Institute, Farmington Hills, Mich., 1995:399-417.
[4] 唐祖全,李卓球,侯作富,徐东亮.导电混凝土电热除冰化雪的功率分析.重庆建筑大学学报,2002,24(3):101-105.
[5] 侯作富,李卓球,唐祖全.融雪化冰用碳纤维导电混凝土的导电性能研究.武汉工业大学学报,2002,24(8):32-34. 
[6] Sherif Yehia, Christopher Y Tuan. Conductive Concrete Overlay for Bridge Deck Deicing. ACI Materials Journal, 1999, 96(3): 382-390.
[7] 唐祖全, 李卓球,徐东亮。 CFRC路面材料的温敏性研究, 武汉理工大学学报, 23(3),  2001:5-7.