摘要

摘要:研究了不确定度在电杆力学试验中的应用,分别对标距测量、支点位移、荷载传感器误差进行了不确定度评定。通过设计建立数学模型,初步分析了各不确定度的来源,并计算了各影响因素的灵敏度系数,最后根据不确定度传播率合成,给出了不确定度分析结果。结果表明,在所有对电杆挠度测量的影响因素中,由于标距L、L2测量的灵敏度系数较小,其对挠度的影响可忽略。
 
Abstract: The application of measurement uncertainty in the mechanical test of circular concrete poles was studied, and the uncertainty of gauge length measurement, fulcrum displacement and load sensor error were evaluated. Through the design of the mathematical model, the source of each uncertainty was analyzed, and the sensitivity coefficients of each influencing factor were calculated. Finally, the uncertainty analysis results were given according to the uncertainty propagation rate synthesis. The analysis shows that in all the factors affecting the deflection measurement of the circular concrete pole, the influence of the gauge length is small, and its influence on the deflection can be negligible.

结论

本文对电杆挠度测量误差的不确定度分析,确定了试验过程中所使用的试验模型,灵敏度系数,并且首次将试验荷载的不确定度纳入挠度的不确定度分析,分析了不确定分量的构成、性质,分别计算了各分量值,最后进行了合成。研究发现在挠度测量的不确定度评定中,标距L、L2的灵敏度系数C4、C5与其它影响因子的灵敏度系数相比,其灵敏度系数较小,因此,标距测量误差引起的不确定度可忽略不计。在实际检测过程中,工程技术人员可以此为例进行相应不确定度计算,以提高检测数据的可信度,保证量值的准确可靠。

参考文献

[1] 陆琛杰,金坤鹏,钱锡颖.新型混凝土电杆挠度测量系统研究[J].混凝土与水泥制品,2018(8):33-36.
 
[2] 李森.混凝土梁试验的挠度测量误差分析[J].浙江建筑,2007,24(6):21-23.
 
[3] 万征,姚仰平,孟达.复杂加载下混凝土的弹塑性本构模型[J].力学学报,2016,48(5):1159-1171.

引用本文

钱锡颖,金坤鹏,陆琛杰,等.环形混凝土电杆挠度测量不确定度分析[J].混凝土与水泥制品,2020(1):33-35+40.
 
QIAN X Y,JIN K P,LU C J,et al.Uncertainty Analysis of Deflection Measurement of Circular Concrete Pole[J].China Concrete and Cement Products,2020(1):33-35+40.

上一个: 早强降黏型复合掺合料对盾构管片混凝土性能的影响

下一个: 方钢管赤泥混凝土黏结滑移性能试验研究

相关文件