摘 要:由于水泥和混凝土技术的发展和进步,有些传统的养护方法现已不能完全适用或部分不能适用。混凝土的开始浇水保湿时间应予提前,应做“尽早及时”,养护保湿持续时间应做到“足够和适可而止”;养护过程中,为保证混凝土结构断面上的温度梯度、升温速率、降温速率适宜及具有较小的最高温度和致裂温度,应在混凝土于半流动状态及塑性阶段实施冷却处理,而在最高温度时加以覆盖并开始保温,并于硬化开始至最高温度到达之间注意防止“热震”的发生。 Abstract: Owing to the development and progress of cement and concrete technology, some traditional curing methods, especially for its regime, aren't suitable completely or partly. Author considers that, the beginning time of watering the concrete for keeping moisture should be advanced as early as possible. And the duration time for watering should be enough, but must stop just at time and not going too long. During the curing process, for the concrete structure section, in order to keep the temperature gradient, their rising rate and cooling rate in a suitable value and the maximum temperature and cracking temperature in a smaller value, the cooling measures should be taken when the concrete is in the semi-flow state and plastic stage. And the concrete should be covered for insulation at the time of maximum temperature and begin to preserve from thermal loss. Pay attention to avoid the “thermal shock” between the time at the beginning of harden and at the occurence of maximum temperature.
英文名 : Consideration and Suggestion on the Curing Methods of Concrete
刊期 : 2009年第2期
关键词 : 养护;热震;温度梯度;内外温差;降温速率;第一零应力时间;第二零应力时间
Key words : Curing; Thermal shock;Temperature gradient;Temperature difference on internal and external;Cooling rate; First zero-stress tim
刊期 : 2009年第2期
DOI :
文章编号 : 1000-4637(2009)02-05-05
基金项目 :
作者 : 邱玉深
单位 : 辽宁省铁岭市第一建筑工程公司, 112004

邱玉深

摘要
参数
结论
参考文献
引用本文

摘   要:由于水泥和混凝土技术的发展和进步,有些传统的养护方法现已不能完全适用或部分不能适用。混凝土的开始浇水保湿时间应予提前,应做“尽早及时”,养护保湿持续时间应做到“足够和适可而止”;养护过程中,为保证混凝土结构断面上的温度梯度、升温速率、降温速率适宜及具有较小的最高温度和致裂温度,应在混凝土于半流动状态及塑性阶段实施冷却处理,而在最高温度时加以覆盖并开始保温,并于硬化开始至最高温度到达之间注意防止“热震”的发生。

Abstract: Owing to the development and progress of cement and concrete technology, some traditional curing methods, especially for its regime, aren't suitable completely or partly. Author considers that, the beginning time of watering the concrete for keeping moisture should be advanced as early as possible. And the duration time for watering should be enough, but must stop just at time and not going too long. During the curing process, for the concrete structure section, in order to keep the temperature gradient, their rising rate and cooling rate in a suitable value and the maximum temperature and cracking temperature in a smaller value, the cooling measures should be taken when the concrete is in the semi-flow state and plastic stage. And the concrete should be covered for insulation at the time of maximum temperature and begin to preserve from thermal loss. Pay attention to avoid the “thermal shock” between the time at the beginning  of harden and at the occurence of  maximum temperature.

关键词:
养护;热震;温度梯度;内外温差;降温速率;第一零应力时间;第二零应力时间
扫二维码用手机看
未找到相应参数组,请于后台属性模板中添加
混凝土冬季施工常常采用蓄热法,即利用对原材料的加热及水泥水化产生的热量,在混凝土浇筑后,通过适当保温来延缓混凝土冷却,使混凝土冷却到0℃以前达到预期要求的强度。蓄热法因具有施工方便、可操作性强等许多优点而被广泛应用。我国行业标准《建筑工程冬季施工规程》(JGJ104-97)第7.3.1条也明文指出,当室外最低温度不低于-15℃时,地面以下的工程,或表面系数M不大于5m-1的结构,应优先采用蓄热法。然而在实际工程中,技术人员往往不去进行热工计算,即使经过了热工计算,也往往在实际施工中尽可能的采用提高原材料温度的方法,以防止混凝土遭受冻害。这样一来,便变成采用“加热混凝土”来“自身御寒”的施工方法,从而使入模的初始浇筑温度T0大大提高。与此相应,混凝土的最高温度T3、致裂温度Tc和内外温差也随之提高,其结果是给混凝土质量的潜在损害和开裂造成有利条件[1~2]。为此,蓄热法施工应采用低温加热的“低温混凝土”,而废弃“高热混凝土”,并通过保温效果良好的覆盖为主要措施来延缓混凝土的冷却,以使混凝土冷却至0℃以前达到预期要求的强度。
所谓“低温混凝土”是指混凝土的初始浇筑温度较低,这就意味着较低的最高温度和致裂温度。同时由于这种混凝土用水量可以减少,也就减小了混凝土的干缩。此外,低温混凝土对于水泥的长期水化、强度和性能发展也有利。因此,低温混凝土既有利于减少温度裂缝的产生,也有利于改善混凝土的潜在质量。由此可见,冬季用蓄热法施工的混凝土,其浇筑初始温度不宜过高,不宜采用过高加热组成材料的方法拌制,除非特别需要,不宜采用“高热混凝土”浇筑。如果确须采用“高热混凝土”施工,也应配以相应的防裂措施。
[1] 富文权, 韩素芳. 混凝土工程裂缝预防与控制[M]. 北京:中国铁道出版社,2007.
[2] 富文权, 韩素芳. 混凝土工程裂缝分析与控制[M]. 北京:中国铁道出版社, 2002.
[3] 阎培渝, 廉慧珍. 用整体论方法分析混凝土的早期开裂及其对策[J]. 建筑技术,2003(1): 15-18.
[4] 安明喆, 朱金铨, 覃维祖. 高性能混凝土自收缩的抑制措施[J]. 混凝土, 2001(5): 37-41.
[5] 中国工程院土木水利与建筑学部工程结构安全性与耐久性研究咨询项目组. 混凝土结构耐久性设计与施工指南[M]. 北京:中国建筑工业出版社,2004.
[6] 邱玉深.大体积混凝土养护的温度控制[J].混凝土,2003(12): 48-49.
[7] 黄士元. 混凝土早期裂纹的成因与防治[J]. 混凝土,2000(7):3-5.
[8] 韩素芳,耿维恕,夏靖华,沙志国. 钢筋混凝土结构裂缝控制指南[M].北京:化学工业出版社, 2006.