自密实混凝土保温复合剪力墙受力性能试验研究
Experimental Research on Mechanical Properties of Self-compacting Concrete Insulation Composite Shearing Wall
2012年第8期
自密实混凝土;保温复合剪力墙;受弯性能;受剪性能
2012年第8期
1000-4637(2012)08-53-04
河北省自然科学基金项目(E2009000073)
李艳艳1, 2,戎 贤1, 2,张健新1, 2
1. 河北工业大学土木工程学院,天津 300401;2. 河北省土木工程技术研究中心,天津 300401

李艳艳1, 2,戎 贤1, 2,张健新1, 2

浏览量:
1000
摘 要:通过4片自密实混凝土保温复合剪力墙受力性能的试验研究,其中第一组为平面外受弯试件,第二组为受剪试件,研究垂直插筋和水平斜插筋对自密实混凝土保温复合剪力墙受力性能的影响,对比分析了自密实混凝土保温复合剪力墙的破坏特征、承载力、刚度及插筋的受力性能等。试验结果表明,垂直插筋和水平斜插形式下的自密实混凝土保温复合剪力墙均具有良好的受力性能,能满足承载力和刚度要求。与水平斜插筋相比,垂直插筋能更好地协调和约束两侧自密实混凝土的变形,使试件具有更高的承载能力和刚度。 Abstract: In order to research the effect of vertical inserted-steel and horizontal inserted-steel on mechanical behavior of self-compacting concrete insulation composite shearing wall, the shearing walls are tested based on the experiment and analysis of 2 groups of 4 specimens, in which the first group is bending specimens and the second group is shearing specimens. And the damage characteristic, bearing capacity, rigidity and stress of inserted-steel of self-compacting concrete insulation composite shearing wall are compared and analyzed. The experimental results show that the self-compacting concrete insulation composite shearing wall with two inserted steel forms all have good mechanical behavior to meet the requirements for bearing capacity and rigidity. Compared with the specimens with horizontal inserted-steel, vertical inserted-steel can better coordinate the deformation of two sides of self-compacting concrete, which makes specimens have higher bearing capacity and rigidity.
英文名 : Experimental Research on Mechanical Properties of Self-compacting Concrete Insulation Composite Shearing Wall
刊期 : 2012年第8期
关键词 : 自密实混凝土;保温复合剪力墙;受弯性能;受剪性能
Key words :
刊期 : 2012年第8期
DOI :
文章编号 : 1000-4637(2012)08-53-04
基金项目 : 河北省自然科学基金项目(E2009000073)
作者 : 李艳艳1, 2,戎 贤1, 2,张健新1, 2
单位 : 1. 河北工业大学土木工程学院,天津 300401;2. 河北省土木工程技术研究中心,天津 300401

李艳艳1, 2,戎 贤1, 2,张健新1, 2

摘要
参数
结论
参考文献
引用本文

摘   要:通过4片自密实混凝土保温复合剪力墙受力性能的试验研究,其中第一组为平面外受弯试件,第二组为受剪试件,研究垂直插筋和水平斜插筋对自密实混凝土保温复合剪力墙受力性能的影响,对比分析了自密实混凝土保温复合剪力墙的破坏特征、承载力、刚度及插筋的受力性能等。试验结果表明,垂直插筋和水平斜插形式下的自密实混凝土保温复合剪力墙均具有良好的受力性能,能满足承载力和刚度要求。与水平斜插筋相比,垂直插筋能更好地协调和约束两侧自密实混凝土的变形,使试件具有更高的承载能力和刚度。

Abstract: In order to research the effect of vertical inserted-steel and horizontal inserted-steel on mechanical behavior of self-compacting concrete insulation composite shearing wall, the shearing walls are tested based on the experiment and analysis of 2 groups of 4 specimens, in which the first group is bending specimens and the second group is shearing specimens. And the damage characteristic, bearing capacity, rigidity and stress of inserted-steel of self-compacting concrete insulation composite shearing wall are compared and analyzed. The experimental results show that the self-compacting concrete insulation composite shearing wall with two inserted steel forms all have good mechanical behavior to meet the requirements for bearing capacity and rigidity. Compared with the specimens with horizontal inserted-steel, vertical inserted-steel can better coordinate the deformation of two sides of self-compacting concrete, which makes specimens have higher bearing capacity and rigidity.

关键词:
自密实混凝土;保温复合剪力墙;受弯性能;受剪性能
扫二维码用手机看
未找到相应参数组,请于后台属性模板中添加
(1)垂直插筋和水平斜插筋两种形式的自密实混凝土保温复合剪力墙的受弯承载力、受剪承载力及抗弯刚度、抗侧移刚度均能够满足正常使用的要求,表现出了良好的受力性能。
(2)垂直插筋较水平斜插的传力更均匀,更有效地传递平面荷载以约束剪力墙两侧混凝土变形,使试件具有更高的承载力和刚度。
(3)插筋在整个受力过程中维持了较低的应力水平,在自密实混凝土保温复合剪力墙的受力过程中所起的作用是协调两侧混凝土变形,约束较薄一侧混凝土。
[1] AGhezal,KH,Khayat.Optimizingself-consolidating concrete with limestone filler by using statistical factorial design methods.ACI Materials Journal, 2002,99(3): 264-272.
[2] Joseph Assaad, Kamal H, Khayat, et,al. Variation of form work pressure with thixotropy of self-consolidating concrete[J]. ACI Materials Journal.2003,100(1):29-37.
[3] 赵筠.自密实混凝土的研究和应用[J].混凝土,2003(6):9-17.
[4] 吴玉杰, 姜国庆. 实用型自密实高性能混凝土配制技术.混凝土与水泥制品,2000(5):49-50.
[5] 李全云. 框剪复合保温板结构体系与住宅节能[J].建筑节能, 2004(3): 39-41.
[6] 李艳艳, 皮凤梅, 乔金丽.自密实混凝土夹芯保温墙板技术改进[J]. 新型建筑材料, 2009(7):36-38.
[7] Christian Greifenhagen, Pierino Lestuzzi. Static cyclic tests on lightly reinforced concrete shear walls[J]. Engineering tructures, 2005, 27(11):1703-1712.
[8] Benayoune A, Samad A A A, Abang Ali A A. Response of pre-cast reinforced composite sandwich panels to axial loading [J]. Construction and Building Materials, 2007,21(3): 677-685.
[9] Benayoune A, Samad A A A, Trikha D N. Structural behavior of eccentrically loaded precast sandwich panels [J]. construction and Building Materials, 2006,20(9): 713-724.
[10] 涂逢祥, 王庆一.我国建筑节能现状及发展[J]. 新型建筑材料, 2004(7): 40-42.