倒置外露灌浆套筒装配式柱脚节点抗震性能 研究
Seismic Behavior of Prefabricated Column Foot Joint with Inverted Exposed Grouting Sleeve
2020年第8期
灌浆套筒;装配式混凝土结构;柱脚节点;自振特性;抗震性能
Grouting sleeve; Prefabricated concrete structure; Foot joint; Natural vibration property; Seismic behavior
2020年第8期
10.19761/j.1000-4637.2020.08.059.06
国家重点研发计划政府间国际科技创新合作重点专项项目(2017YFE0195300);山东省自然科学基金项目(ZR2017BEE022)。
乔德浩1,倪韦斌1,王少杰1,庞加宝2,胡兆文2,黄兴淮3
1.山东农业大学 水利土木工程学院,山东 泰安 271018;2.山东德建集团工程技术研究院,山东 德州 253000;3.东南大学 土木工程学院,江苏 南京 210096

乔德浩1,倪韦斌1,王少杰1,庞加宝2,胡兆文2,黄兴淮3

乔德浩,倪韦斌,王少杰,等.倒置外露灌浆套筒装配式柱脚节点抗震性能研究[J].混凝土与水泥制品,2020(8):59-64.

QIAO D H,NI W B,WANG S J,et al.Seismic Behavior of Prefabricated Column Foot Joint with Inverted Exposed Grouting Sleeve[J].China Concrete and Cement Products,2020(8):59-64.

浏览量:
1000
摘   要:通过自振特性测试和竖向荷载作用下的低周往复荷载试验,对比分析了倒置外露灌浆套筒装配式柱脚节点与传统现浇及现行装配式柱脚节点的整体性及抗震性能。结果表明,倒置外露灌浆套筒柱脚节点试件(NPC)的整体性与传统现浇试件(RC)基本相当,现行装配试件(TPC)测试所得的各阶自振频率基本均低于RC和NPC。三种柱脚节点在失效破坏时均出现了塑性铰,且两个装配式柱脚节点较现浇试件其塑性铰、柱身开裂高度均上移约1个灌浆套筒高度,宜适当延长箍筋加密区。三种柱脚节点的刚度退化规律相同,延性系数均在3.0以上,NPC的耗能能力显著优于RC和TPC。RC、TPC、NPC对应的开裂位移角分别为1/430、1/393、1/479,对应的极限位移角分别为1/24、1/22、1/22,均分别大于规范限值,满足抗震设防要求。 Abstract: Through test of natural vibration property and horizontal low cycle reciprocating load test under vertical load, the integrity and seismic behavior of the inverted exposed grouting sleeve prefabricated column foot joint and the traditional cast-in-place and current prefabricated column base joint were compared and analyzed. The results show that the integrity of the specimen of inverted exposed grouting sleeve column base joint (NPC) is the same as that of the traditional cast-in-place specimen (RC). The natural frequencies of current assembled specimen (TPC) are lower than those of RC and NPC. Plastic hinge appears in all three kinds of column foot joints when they failed, and the height of plastic hinge and column body crack of two prefabricated column foot joints moves up about one grouting sleeve height compared with RC, the densified area of stirrup should be extended properly. The stiffness degradation law of the specimens is the same, the ductility factors are all above 3.0, and the energy dissipation capacity of NPC is significantly better than that of RC and TPC. The corresponding crack displacement angles of RC, TPC and NPC are 1/430, 1/393 and 1/479 respectively, and the corresponding limiting displacement drift are 1/24, 1/22 and 1/22 respectively, which are greater than the code limits, meeting the seismic fortification requirements.
英文名 : Seismic Behavior of Prefabricated Column Foot Joint with Inverted Exposed Grouting Sleeve
刊期 : 2020年第8期
关键词 : 灌浆套筒;装配式混凝土结构;柱脚节点;自振特性;抗震性能
Key words : Grouting sleeve; Prefabricated concrete structure; Foot joint; Natural vibration property; Seismic behavior
刊期 : 2020年第8期
DOI : 10.19761/j.1000-4637.2020.08.059.06
文章编号 :
基金项目 : 国家重点研发计划政府间国际科技创新合作重点专项项目(2017YFE0195300);山东省自然科学基金项目(ZR2017BEE022)。
作者 : 乔德浩1,倪韦斌1,王少杰1,庞加宝2,胡兆文2,黄兴淮3
单位 : 1.山东农业大学 水利土木工程学院,山东 泰安 271018;2.山东德建集团工程技术研究院,山东 德州 253000;3.东南大学 土木工程学院,江苏 南京 210096

乔德浩1,倪韦斌1,王少杰1,庞加宝2,胡兆文2,黄兴淮3

乔德浩,倪韦斌,王少杰,等.倒置外露灌浆套筒装配式柱脚节点抗震性能研究[J].混凝土与水泥制品,2020(8):59-64.

QIAO D H,NI W B,WANG S J,et al.Seismic Behavior of Prefabricated Column Foot Joint with Inverted Exposed Grouting Sleeve[J].China Concrete and Cement Products,2020(8):59-64.

摘要
参数
结论
参考文献
引用本文

摘   要:通过自振特性测试和竖向荷载作用下的低周往复荷载试验,对比分析了倒置外露灌浆套筒装配式柱脚节点与传统现浇及现行装配式柱脚节点的整体性及抗震性能。结果表明,倒置外露灌浆套筒柱脚节点试件(NPC)的整体性与传统现浇试件(RC)基本相当,现行装配试件(TPC)测试所得的各阶自振频率基本均低于RC和NPC。三种柱脚节点在失效破坏时均出现了塑性铰,且两个装配式柱脚节点较现浇试件其塑性铰、柱身开裂高度均上移约1个灌浆套筒高度,宜适当延长箍筋加密区。三种柱脚节点的刚度退化规律相同,延性系数均在3.0以上,NPC的耗能能力显著优于RC和TPC。RC、TPC、NPC对应的开裂位移角分别为1/430、1/393、1/479,对应的极限位移角分别为1/24、1/22、1/22,均分别大于规范限值,满足抗震设防要求。

Abstract: Through test of natural vibration property and horizontal low cycle reciprocating load test under vertical load, the integrity and seismic behavior of the inverted exposed grouting sleeve prefabricated column foot joint and the traditional cast-in-place and current prefabricated column base joint were compared and analyzed. The results show that the integrity of the specimen of inverted exposed grouting sleeve column base joint (NPC) is the same as that of the traditional cast-in-place specimen (RC). The natural frequencies of current assembled specimen (TPC) are lower than those of RC and NPC. Plastic hinge appears in all three kinds of column foot joints when they failed, and the height of plastic hinge and column body crack of two prefabricated column foot joints moves up about one grouting sleeve height compared with RC, the densified area of stirrup should be extended properly. The stiffness degradation law of the specimens is the same, the ductility factors are all above 3.0, and the energy dissipation capacity of NPC is significantly better than that of RC and TPC. The corresponding crack displacement angles of RC, TPC and NPC are 1/430, 1/393 and 1/479 respectively, and the corresponding limiting displacement drift are 1/24, 1/22 and 1/22 respectively, which are greater than the code limits, meeting the seismic fortification requirements.

关键词:
套筒
the
of
and
rc
npc
柱脚
column
are
tpc
扫二维码用手机看
未找到相应参数组,请于后台属性模板中添加

(1)自振特性测试结果表明,柱脚节点试件的整体性仍以RC最优,NPC的整体性与RC基本相当,TPC各阶自振频率基本均低于RC、NPC。
(2)失效破坏时,各柱脚节点试件均出现了塑性铰,两个装配式柱脚节点较传统现浇试件的塑性铰、柱身开裂高度均上移约1个灌浆套筒高度,宜适当延长箍筋加密区。  
(3)NPC对应的屈服荷载、极限荷载、破坏荷载均高于RC、TPC,开裂荷载略微下降。三种柱脚节点的刚度退化规律相同,延性系数均在3.0以上,NPC的耗能能力显著优于RC、TPC。
 (4)RC、TPC、NPC的开裂位移角分别为1/430、1/393、1/479,极限位移角分别为1/24、1/22、1/22,均分别大于规范限值,满足抗震设防要求。

[1] 吴刚,冯德成.装配式混凝土框架节点基本性能研究进展[J].建筑结构学报,2018,39(2):1-16.
[2] 穆立春,胡兆文,张迎建,等.外露倒置钢筋灌浆套筒预制混凝土柱及施工方法:CN108930360A[P].2018-12-04.
[3] 张志,许园林,王振宇,等.装配式剪力墙节点抗弯承载力现场试验[J].混凝土与水泥制品,2019(8):58-62.
[4] 许成顺,刘洪涛,杜修力.高应力反复拉压作用下钢筋套筒灌浆连接性能试验研究[J].建筑结构学报,2018,39(12):178-184,193.
[5] YAN Q S,CHEN T Y,XIE Z Y.Seismic experimental study on a precast concrete beam-column connection with grout sleeves[J].Engineering Structures,2018,155:330-344.
[6] 匡志平,郑冠雨,焦雪涛.灌浆不足对钢筋套筒连接力学性能影响试验[J].同济大学学报(自然科学版),2019,47(7):934-945.
[7] MA Y F,LI S L,WU Y Q,et al.Acoustic emission testing method for the sleeve grouting compactness of fabricated structure[J].Construction and Building Materials,2019,221:800-810.
[8] 郑清林,王霓,陶里,等.套筒灌浆缺陷对装配式混凝土柱抗震性能影响的试验研究[J].土木工程学报,2018,51(5):75-83.
[9] 姜绍飞,蔡婉霞.灌浆套筒密实度的超声波检测方法[J].振动与冲击,2018,37(10):43-49.
[10] 郑永峰,郭正兴,曹江.新型灌浆套筒的约束机理及约束应力分布[J].哈尔滨工业大学学报,2015,47(12):106-111.
[11] 葛继平,闫兴非,王志强.机械套筒连接的轨道交通预制拼装桥墩抗震性能试验研究[J].地震工程与工程振动,2017,37(6):143-153.
[12] LU Z W,HUANG J,DAI S B,et al.Experimental study on a precast beam-column joint with double grouted splice sleeves[J].Engineering Structures,2019,199:109589.
[13] 中华人民共和国住房和城乡建设部.钢筋机械连接技术规程:JGJ 107—2016[S].北京:中国建筑工业出版社,2016.
[14] 中华人民共和国住房和城乡建设部.建筑抗震试验规程:JGJ/T 101—2015[S].北京:中国建筑工业出版社,2015.
[15] ANIL K C.Dynamics of Structures[M].4th ed.New York:Pearson,2011.
[16] 刘文超,曹万林,张克胜,等.装配式轻钢框架-复合轻墙结构抗震性能试验研究[J/OL].建筑结构学报,2019(10)[2020-03-05].https://doi.org/10.14006/j.jzjgxb.2018.0340.
[17] 过镇海,时旭东.钢筋混凝土原理和分析[M].北京:清华大学出版社,2003:334-442.
[18] 余琼,匡轩,方永青.钢筋套筒灌浆搭接连接的预制框架柱抗震试验[J].同济大学学报(自然科学版),2019,47(1):18-28,37.
[19] 中华人民共和国住房和城乡建设部,中华人民共和国国家质量监督检验检疫总局.建筑抗震设计规范:GB 50011—2010[S].北京:中国建筑工业出版社,2016.

乔德浩,倪韦斌,王少杰,.倒置外露灌浆套筒装配式柱脚节点抗震性能研究[J].混凝土与水泥制品,2020(8):59-64.

QIAO D H,NI W B,WANG S J,et al.Seismic Behavior of Prefabricated Column Foot Joint with Inverted Exposed Grouting Sleeve[J].China Concrete and Cement Products,2020(8):59-64.

相关文件

暂时没有内容信息显示
请先在网站后台添加数据记录。

关注《混凝土与水泥制品》

总访问量 468,401   网站统计

官方微信公众号关闭
苏州混凝土水泥制品研究院有限公司

关于我们    |    联系我们    |    订购杂志    |    回到顶部

版权所有:中国混凝土与水泥制品网  苏ICP备10086386号   网站建设:中企动力 苏州

版权所有:中国混凝土与水泥制品网

苏ICP备10086386号

网站建设:中企动力 苏州