预制混凝土夹心保温外墙板拉结件系统火灾后性能研究
Performance study on connector system of precast concrete sandwich wall after fire
2023年第12期
预制混凝土夹心保温墙;火灾;不锈钢拉结件;抗剪性能
Precast concrete sandwich insulation wall; Fire; Stainless steel connector; Shear behavior
2023年第12期
10.19761/j.1000-4637.2023.12.073.06
张国来1,赵 毅2,*,田 东3,周 剑2,王聪颖1,卢晓岩1,任 烨3,刘 畅3
1.北京城建房地产开发有限公司,北京 100032;2.中国建筑科学研究院有限公司,北京 100013; 3.北京市建筑设计研究院有限公司,北京 100045

张国来1,赵 毅2,*,田 东3,周 剑2,王聪颖1,卢晓岩1,任 烨3,刘 畅3

张国来,赵毅,田东,等.预制混凝土夹心保温外墙板拉结件系统火灾后抗剪性能研究[J].混凝土与水泥制品,2023(12):73-78.

ZHANG G L,ZHAO Y,TIAN D,et al.Performance study on shear behavior of connector system of precast concrete sandwich wall after fire[J].China Concrete and Cement Products,2023(12):73-78.

浏览量:
1000
摘   要:为研究预制混凝土夹心保温外墙板中不锈钢拉结件系统在火灾后的抗剪性能,以某实体项目拆除墙板为研究对象,通过3 h内叶板和1 h外叶板的耐火试验模拟火灾的影响,分别进行了耐火试验前后非破坏性力学试验和耐火试验后破坏性力学试验,并与板式拉结件标准剪切试件进行了对比。结果表明:受极端火灾影响后,不锈钢拉结件系统抗剪承载力明显降低,但仍可达到拉结件设计对应的承载力试验值的1.6倍;不锈钢拉结件系统抗剪刚度明显降低,但在自重荷载标准值作用下位移约1.0 mm,低于北京市地方标准规定的限值2.5 mm;大位移时的破坏模式仍为拉结件受压侧失稳与受拉侧混凝土锚固破坏,且荷载下降不超过峰值荷载的15%。 Abstract: In order to study the shear performance of the stainless steel connector system on precast concrete sandwich insulation exterior wall panel after fire, taking the demolition wall panel of a physical project as the research object, the fire impact was simulated through the fire resistance test of 3 h inner leaf plate and 1 h outer leaf, and the non-destructive comparative mechanical test before and after fire resistance test and destructive mechanical test after fire resistance test were carried out and compared to the standard shear specimen. The results show that after being affected by extreme fire, the shear bearing capacity of the stainless steel connector system is significantly reduced, but it can still reach 1.6 times the corresponding bearing capacity test value of the tension joint design. The shear stiffness of the stainless steel tie joint system is significantly reduced, but the displacement is about 1.0 mm under the action of the self-weight load standard value, which is lower than the limit value 2.5 mm stipulated by the local standard of Beijing. The failure mode at large displacement is still the buckling of the compression side of the tie joint and the anchorage failure of the concrete on the tensile side, and the load drop does not exceed 15% of the peak load.
英文名 : Performance study on connector system of precast concrete sandwich wall after fire
刊期 : 2023年第12期
关键词 : 预制混凝土夹心保温墙;火灾;不锈钢拉结件;抗剪性能
Key words : Precast concrete sandwich insulation wall; Fire; Stainless steel connector; Shear behavior
刊期 : 2023年第12期
DOI : 10.19761/j.1000-4637.2023.12.073.06
文章编号 :
基金项目 :
作者 : 张国来1,赵 毅2,*,田 东3,周 剑2,王聪颖1,卢晓岩1,任 烨3,刘 畅3
单位 : 1.北京城建房地产开发有限公司,北京 100032;2.中国建筑科学研究院有限公司,北京 100013; 3.北京市建筑设计研究院有限公司,北京 100045

张国来1,赵 毅2,*,田 东3,周 剑2,王聪颖1,卢晓岩1,任 烨3,刘 畅3

张国来,赵毅,田东,等.预制混凝土夹心保温外墙板拉结件系统火灾后抗剪性能研究[J].混凝土与水泥制品,2023(12):73-78.

ZHANG G L,ZHAO Y,TIAN D,et al.Performance study on shear behavior of connector system of precast concrete sandwich wall after fire[J].China Concrete and Cement Products,2023(12):73-78.

摘要
参数
结论
参考文献
引用本文

摘   要:为研究预制混凝土夹心保温外墙板中不锈钢拉结件系统在火灾后的抗剪性能,以某实体项目拆除墙板为研究对象,通过3 h内叶板和1 h外叶板的耐火试验模拟火灾的影响,分别进行了耐火试验前后非破坏性力学试验和耐火试验后破坏性力学试验,并与板式拉结件标准剪切试件进行了对比。结果表明:受极端火灾影响后,不锈钢拉结件系统抗剪承载力明显降低,但仍可达到拉结件设计对应的承载力试验值的1.6倍;不锈钢拉结件系统抗剪刚度明显降低,但在自重荷载标准值作用下位移约1.0 mm,低于北京市地方标准规定的限值2.5 mm;大位移时的破坏模式仍为拉结件受压侧失稳与受拉侧混凝土锚固破坏,且荷载下降不超过峰值荷载的15%。

Abstract: In order to study the shear performance of the stainless steel connector system on precast concrete sandwich insulation exterior wall panel after fire, taking the demolition wall panel of a physical project as the research object, the fire impact was simulated through the fire resistance test of 3 h inner leaf plate and 1 h outer leaf, and the non-destructive comparative mechanical test before and after fire resistance test and destructive mechanical test after fire resistance test were carried out and compared to the standard shear specimen. The results show that after being affected by extreme fire, the shear bearing capacity of the stainless steel connector system is significantly reduced, but it can still reach 1.6 times the corresponding bearing capacity test value of the tension joint design. The shear stiffness of the stainless steel tie joint system is significantly reduced, but the displacement is about 1.0 mm under the action of the self-weight load standard value, which is lower than the limit value 2.5 mm stipulated by the local standard of Beijing. The failure mode at large displacement is still the buckling of the compression side of the tie joint and the anchorage failure of the concrete on the tensile side, and the load drop does not exceed 15% of the peak load.

扫二维码用手机看
未找到相应参数组,请于后台属性模板中添加

(1)依据GB 50016—2018要求,对采用不锈钢拉结件系统的夹心保温外墙板进行了严苛的耐火试验,试件保温层被烧毁,背火面有明显温升,可以反映极端条件下火灾的不利影响。
(2)受火灾影响,拉结件系统受剪承载力与刚度明显降低,但剩余承载力仍可达到拉结件设计对应的承载力试验值的1.6倍;在自重荷载标准值作用下位移约1.0 mm,低于北京市地方标准规定的限值2.5 mm;在大位移时的破坏模式仍为拉结件受压侧失稳与受拉侧混凝土锚固破坏,且荷载下降不超过峰值荷载的15%。
(3)整体而言,夹心保温外墙板采用的不锈钢拉结件系统在火灾后仍可满足正常使用要求,且具有较高的安全性能和可修复潜力,适宜在装配式建筑中进一步推广应用。

[1] 熊峰,边钰,刘烨,等.预制混凝土夹心保温墙板结构性能研究综述[J].建筑结构,2012,52(23):26-34,125.
[2] 吴学淑,李进军,王平山,等.预制混凝土夹心保温墙应用研究进展[J].建筑结构,2021,51(增刊):1197-1202.
[3] 欧志华,刘锡军,王彦.建筑外墙外保温系统的火灾特征及防火措施[J].建筑科学,2010,26(11):33-35.
[4] 李志杰,薛伟辰.预制混凝土无机保温夹心外墙体抗火性能试验研究[J].建筑结构学报,2015,36(1):59-67.
[5] 李志杰,秦桁,刘国权,等.预制夹芯保温墙体板缝抗火性能试验研究[J].建筑结构,2012,42(10):106-109.
[6] 杨佳林,薛伟辰,栗新.预制夹芯保温墙体FRP连接件的力学性能试验[J].江苏大学学报(自然科学版),2013,34(6):723-729.
[7] 薛伟辰,张赛,苏瑞佳,等.预制混凝土夹心保温墙体棒状不锈钢连接件研发与抗拔性能试验研究[J].施工技术,2018,47(12):92-94.
[8] 薛伟辰,姜伟庆,宋佳峥,等.预制混凝土夹心保温外挂墙体桁架式不锈钢连接件抗拔与抗剪性能试验研究[J].施工技术, 2018,47(12):95-99.
[9] 章润涛,蒋超,王健飞.预制夹心墙体GFRP拉结件抗剪性能试验研究[J].建筑结构,2019,49(增刊):911-913.
[10] 吕安安,张绍武,赵志刚,等.超低能耗保温夹芯墙板金属夹形拉结件受力性能分析[J].混凝土与水泥制品,2020(5):61-65,91.
[11] 尹展.预制混凝土夹芯保温墙内外叶墙体连接性能研究[D].沈阳:沈阳建筑大学,2020.
[12] 郑旭,郑勇,刘海成,等.夹心保温外墙板用不锈钢拉结件抗剪承载力研究[J].混凝土与水泥制品,2020(12):63-67.
[13] 北京市住房和城乡建设委员会,北京市市场监督管理局.预制混凝土夹心保温外墙板应用技术规程:DB11/T 2128—2023[S].北京:中国标准出版社,2023.
[14] 中华人民共和国国家质量监督检验检疫总局,中国国家标准化管理委员会.金属材料 拉伸试验 第1部分:室温试验方法:GB/T 228.1—2010[S].北京:中国标准出版社,2011.
[15] 中华人民共和国住房和城乡建设部.建筑设计防火规范(2018年版):GB 50016—2018[S].北京:中国计划出版社,2018.
[16] 中华人民共和国国家质量监督检验检疫总局,中国国家标准化管理委员会.建筑构件耐火试验方法 第1部分:通用要求:GB/T 9978.1—2008[S].北京:中国标准出版社,2008.

张国来,赵毅,田东,.预制混凝土夹心保温外墙板拉结件系统火灾后抗剪性能研究[J].混凝土与水泥制品,2023(12):73-78.

ZHANG G L,ZHAO Y,TIAN D,et al.Performance study on shear behavior of connector system of precast concrete sandwich wall after fire[J].China Concrete and Cement Products,2023(12):73-78.

相关文件

暂时没有内容信息显示
请先在网站后台添加数据记录。

关注《混凝土与水泥制品》

总访问量 468,401   网站统计

官方微信公众号关闭
苏州混凝土水泥制品研究院有限公司

关于我们    |    联系我们    |    订购杂志    |    回到顶部

版权所有:中国混凝土与水泥制品网  苏ICP备10086386号   网站建设:中企动力 苏州

版权所有:中国混凝土与水泥制品网

苏ICP备10086386号

网站建设:中企动力 苏州