苏州混凝土水泥制品研究院有限公司

头部文案

发布时间:2020-01-06 00:00:00
全国建材科技期刊
全国中文核心期刊
中国科技论文统计源期刊
万方数据-数字化期刊群入网期刊
中国学术期刊(光盘版)全文收录期刊
华东地区优秀科技期刊
江苏省期刊方阵“双效期刊”
中国期刊网全文收录期刊
中国科技期刊数据库全文收录期刊
装配式地铁车站单面叠合侧墙受力性能试验研究
Experimental study on mechanical properties of single-sided laminated side walls of assembled metro station
2024年第3期
地铁车站;装配式结构;单面叠合侧墙;力学性能
Metro station; Assembled structure; Single-sided laminated side wall; Mechanical property
2024年第3期
10.19761/j.1000-4637.2024.03.039.04
国家重点研发计划项目(2016YFC0701703)。
卞 波1,2,莫振泽1,2,周梓彬1,3,杨智学4,李婉清5
1.锡澄中车(无锡)城市轨道交通工程有限公司,江苏 无锡 214400;2.无锡地铁集团有限公司, 江苏 无锡 214044;3.江苏中车城市发展有限公司,江苏 无锡 214000;4.中铁一局集团城市轨道 交通工程有限公司,江苏 无锡 214000;5.东南大学 土木工程学院,江苏 南京 211189

卞 波1,2,莫振泽1,2,周梓彬1,3,杨智学4,李婉清5

卞波,莫振泽,周梓彬,等.装配式地铁车站单面叠合侧墙受力性能试验研究[J].混凝土与水泥制品,2024(3):39-42.

BIAN B,MO Z Z,ZHOU Z B,et al.Experimental study on mechanical properties of single-sided laminated side walls of assembled metro station[J].China Concrete and Cement Products,2024(3):39-42.

浏览量:
1000
摘   要:为提高地铁车站施工效率,研发了装配式地铁车站单面叠合侧墙,分别制作了缩尺比例为1∶2的叠合试件和现浇试件,并进行了抗弯试验。结果表明:现浇试件和叠合试件呈现出相同的破坏形态,两者的荷载-挠度曲线基本接近,抗弯性能相近;叠合试件的叠合面未出现明显破坏,且截面钢筋应变分布仍满足平截面假定,叠合试件的整体性较好;装配式地铁车站单面叠合侧墙具有“等同现浇”的受力性能,可应用于实际工程。 Abstract: In order to improve the construction efficiency of metro station, a single-sided laminated side wall of assembled metro station was developed. A laminated and cast-in-place specimens were made with a scale ratio of 1∶2, and bending tests were conducted. The test results show that the laminated and cast-in-place specimens have the same damage pattern, and the load-deflection curves are basically close to each other, which have the similar bending performance. No obvious damage occurrs on the surface of the laminated specimen, and the strain distribution of the section reinforcement still satisfies the assumption of flat section, indicating that the integrity of the specimen force is good. The single-sided laminated side wall of assembled metro stations has the "equivalent cast-in-place" mechanical performance and can be safely applied to the actual project.
英文名 : Experimental study on mechanical properties of single-sided laminated side walls of assembled metro station
刊期 : 2024年第3期
关键词 : 地铁车站;装配式结构;单面叠合侧墙;力学性能
Key words : Metro station; Assembled structure; Single-sided laminated side wall; Mechanical property
刊期 : 2024年第3期
DOI : 10.19761/j.1000-4637.2024.03.039.04
文章编号 :
基金项目 : 国家重点研发计划项目(2016YFC0701703)。
作者 : 卞 波1,2,莫振泽1,2,周梓彬1,3,杨智学4,李婉清5
单位 : 1.锡澄中车(无锡)城市轨道交通工程有限公司,江苏 无锡 214400;2.无锡地铁集团有限公司, 江苏 无锡 214044;3.江苏中车城市发展有限公司,江苏 无锡 214000;4.中铁一局集团城市轨道 交通工程有限公司,江苏 无锡 214000;5.东南大学 土木工程学院,江苏 南京 211189

卞 波1,2,莫振泽1,2,周梓彬1,3,杨智学4,李婉清5

卞波,莫振泽,周梓彬,等.装配式地铁车站单面叠合侧墙受力性能试验研究[J].混凝土与水泥制品,2024(3):39-42.

BIAN B,MO Z Z,ZHOU Z B,et al.Experimental study on mechanical properties of single-sided laminated side walls of assembled metro station[J].China Concrete and Cement Products,2024(3):39-42.

摘要
参数
结论
参考文献
引用本文

摘   要:为提高地铁车站施工效率,研发了装配式地铁车站单面叠合侧墙,分别制作了缩尺比例为1∶2的叠合试件和现浇试件,并进行了抗弯试验。结果表明:现浇试件和叠合试件呈现出相同的破坏形态,两者的荷载-挠度曲线基本接近,抗弯性能相近;叠合试件的叠合面未出现明显破坏,且截面钢筋应变分布仍满足平截面假定,叠合试件的整体性较好;装配式地铁车站单面叠合侧墙具有“等同现浇”的受力性能,可应用于实际工程。

Abstract: In order to improve the construction efficiency of metro station, a single-sided laminated side wall of assembled metro station was developed. A laminated and cast-in-place specimens were made with a scale ratio of 1∶2, and bending tests were conducted. The test results show that the laminated and cast-in-place specimens have the same damage pattern, and the load-deflection curves are basically close to each other, which have the similar bending performance. No obvious damage occurrs on the surface of the laminated specimen, and the strain distribution of the section reinforcement still satisfies the assumption of flat section, indicating that the integrity of the specimen force is good. The single-sided laminated side wall of assembled metro stations has the "equivalent cast-in-place" mechanical performance and can be safely applied to the actual project.

扫二维码用手机看
未找到相应参数组,请于后台属性模板中添加

(1)单面叠合墙的破坏形态与现浇试件相同,均表现为剪切破坏,叠合面未出现明显界面裂缝,两者受力及破坏机制相似。
(2)单面叠合墙由于侧墙预制部分的混凝土强度等级较高,其荷载-挠度曲线稍高于现浇试件,表现出更好的承载力及刚度性能。
(3)单面叠合墙的跨中截面钢筋应变分布仍符合平截面假定,可靠的叠合面黏结性能使试件仍具有较好的整体性。
(4)单面叠合墙底部采用水洗露骨料粗糙面、侧面采用凿毛粗糙面的单面叠合侧墙试件可实现“等同现浇”受力性能,可安全应用于实际工程。

[1] YEE A A.Structural and economic benefits of precast/prestressed concrete construction[J].PCI Journal,2001,46(4):34-43.
[2] YEE A A.Social and environmental benefits of precast concrete technology[J].PCI Journal,2001,46(3):14-19.
[3] 陈湘生,王雷,阳文胜,等.双洞密贴顶管法装配式地铁车站建造方案及其力学性能研究[J].隧道建设(中英文),2023,43(7):1089-1098.
[4] 莫振泽,冯帅克,卞波,等.装配式地铁车站叠合顶板受力性能试验研究[J/OL].铁道科学与工程学报,2023(10):1-10[2023-11-10].https://doi.org/10.19713/j.cnki.43-1423/u.T20231127.
[5] 欧飞奇.地铁预制装配式车站结构抗震性能数值研究[J].现代城市轨道交通,2023(9):81-88.
[6] 陈俊达,谷倩,段攀,等.双面叠合混凝土剪力墙大偏心受压性能试验研究[J/OL].工业建筑,2023(6):1-13[2023-11-10].https://doi.org/10.13204/j.gyjzG23012801.
[7] 王宁,王洪欣,樊则森,等.双面叠合剪力墙应用及平面内抗震性能研究[J].建筑结构,2023,53(14):27-32.
[8] 曹任辉,彭波,任靖,等.双面叠合剪力墙水平接缝传力性能试验研究[J].建筑结构,2023,53(14):19-26.
[9] 余少乐,杨联萍,亓立刚,等.基于软化拉压杆模型的双面叠合剪力墙水平连接节点承载力分析[J].建筑结构,2021,51(23):120-126.
[10] 王平山,纵斌,李进军,等.低层双面叠合夹心保温剪力墙结构设计与应用研究[J].建筑结构,2022,52(23):1-6,86.
[11] 林睿,李振宝,王文静,等.夹心保温双面叠合剪力墙受力性能研究进展[J].建筑结构,2023,53(11):88-96,142.
[12] 中华人民共和国住房和城乡建设部.混凝土结构设计规范(2015年版):GB 50010—2010[S].北京:中国建筑工业出版社,2010.

卞波,莫振泽,周梓彬,.装配式地铁车站单面叠合侧墙受力性能试验研究[J].混凝土与水泥制品,2024(3):39-42.

BIAN B,MO Z Z,ZHOU Z B,et al.Experimental study on mechanical properties of single-sided laminated side walls of assembled metro station[J].China Concrete and Cement Products,2024(3):39-42.

相关文件

暂时没有内容信息显示
请先在网站后台添加数据记录。

关注《混凝土与水泥制品》

总访问量 468,401   网站统计

官方微信公众号关闭
苏州混凝土水泥制品研究院有限公司

关于我们    |    联系我们    |    订购杂志    |    回到顶部

版权所有:中国混凝土与水泥制品网  苏ICP备10086386号   网站建设:中企动力 苏州

版权所有:中国混凝土与水泥制品网

苏ICP备10086386号

网站建设:中企动力 苏州