蒸压加气混凝土制品热耗和节能途径分析
Analysis on Heat Consumption and Energy Saving Way of Autoclaved Aerated Concrete(ACC) Products
关键词:
能耗;热平衡;蒸汽热能;蒸压加气混凝土制品
Key words:
Energy consumption; Thermal balance; Steam heat energy; Autoclaved aerated concrete product
刊期:
2019年第6期
DOI:
10.19761/j.1000-4637.2019.06.034.04
文章编号:
基金项目:
“十三五”国家重点研发计划重点专项(2016YFC0700802)
作者:
陆 洁, 刘品德, 丁小龙, 张叶信
单位:
安徽科达机电有限公司,马鞍山 243000
摘要
摘 要:从蒸压热平衡角度分析了B05级蒸压加气混凝土制品生产线的热耗和节能途径。结果表明,干密度每相差100 kg/m3,能耗相差16.5 kg蒸汽热能;坯体水料比每差1%,蒸汽能耗相差约1 kg/m3;与进釜坯体温度80 ℃相比,进釜坯体温度50 ℃,需多加蒸汽23 kg/m3,进釜坯体温度30 ℃,需多加蒸汽38 kg/m3;与蒸压釜初始温度70 ℃相比,冷釜升温(设20 ℃)需增加蒸汽量11.33 kg/m3,蒸压釜初始温度40 ℃,蒸压釜升温需要增加蒸汽量6.8 kg/m3;蒸压釜矿棉保护层厚度为200 mm和100 mm比较,蒸压釜散热损失使每m3制品减少约2 kg/m3;尾气排放热能相当于29.25 kg/m3蒸汽热能;每m3制品产生冷凝水热能为29.5 kg/m3蒸汽热能。
Abstract: From the view of thermal balance, the heat consumption and energy saving ways of B05 autoclaved aerated concrete(ACC) product production line are analyzed. The results show that when the dry density is 100 kg/m3, the energy consumption difference is 16.5 kg. The steam energy consumption is 1 kg/m3 when the water-solid ratio is 1%. Compared with the ACC body temperature of 80 ℃ before autoclave, if the temperature of the ACC body is 50 ℃, extra 23 kg steam is needed for 1 m3. If the temperature is 30 ℃, extra 38 kg steam is needed for 1 m3. Compared with the initial temperature of autoclave 70 ℃, if the cold autoclave temperature is 20 ℃, 11.3 kg steam is needed for 1 m3. If the temperature is 40 ℃, extra 6.8 kg steam is needed for 1 m3. Comparing autoclave mineral wool protective layer thickness of 200 mm with 100 mm, autoclave heat loss reduces about 2 kg/m3 of products. The exhaust heat is equivalent to 29.25 kg/m3 of steam. The heat energy of condensed water for product is 29.5 kg/m3 steam heat energy.
结论
(1)不同干密度所需能耗不同,干密度每相差100 kg/m3,蒸汽能耗相差约16.5 kg/m3。随着干密度下降,制品能耗也将下降。
(2)坯体水料比每相差1%,能耗相差约1 kg/m3,在满足工艺发气要求下,可通过降低水料比来降低能耗。
(3)B05级制品坯体每上升1 ℃,需要增加能耗1 515.3 kJ/m3,折合蒸汽量0.763 6 kg/m3。与进釜坯体温度80 ℃相比,进釜坯体温度为50 ℃时需多增加蒸汽23 kg/m3;进釜坯体温度30 ℃需多增加蒸汽38 kg/m3。从降低能耗角度出发考虑,应当配置釜前静停室。
(4)坯体进出釜过程中应尽量保持蒸压釜内温度不变。蒸压釜初始温度每下降1 ℃,蒸压釜升温需增加蒸汽量0.226 8 kg/m3。与蒸压釜初始温度70 ℃相比,冷釜(20 ℃)升温需增加蒸汽量11.33 kg/m3;蒸压釜初始温度40 ℃,蒸压釜升温需增加蒸汽量6.8 kg/m3。
(5)对B05级制品而言,每釜排放冷凝水热量为6 387 440 kJ,即每m3制品产生的冷凝水热能为29.5 kg蒸汽热能。如仅用作保持静停窑温度,热效率为12%左右。
参考文献
引用本文
陆洁,刘品德,丁小龙,等.蒸压加气混凝土制品热耗和节能途径分析[J].混凝土与水泥制品,2019(6):34-37.
LU J,LIU P D,DING X L,et al.Analysis on Heat Consumption and Energy Saving Way of Autoclaved Aerated Concrete (ACC) Products[J].China Concrete and Cement Products,2019(6):34-37.