预制混凝土综合管廊接口密封设计方法
Methods for Seal Design of Interface of Precast Concrete Utility Tunnel
关键词:
预制混凝土综合管廊;接口形式;密封设计;工程质量
Key words:
Precast concrete utility tunnel; Interface form; Seal design; Engineering quality
刊期:
2018年第1期
DOI:
文章编号:
1000-4637(2018)-01-35-08
基金项目:
作者:
曹生龙
单位:
北京市市政工程研究院,100037
摘要
摘 要:结合多年实际工程经验,总结了近几年工程中预制混凝土综合管廊接口出现的问题,并提出了相应推荐的接口形式,最后给出了预制混凝土综合管廊的接口密封设计方法,以期为预制混凝土综合管廊接口密封设计提供参考,促进预制混凝土综合管廊的工程质量进一步改进提高。
Abstract: Based on years of practical experience, the interface problems of precast concrete utility tunnel in recent years are concluded, the corresponding interface forms recommended are put forward, the interface sealing design methods of precast concrete utility tunnel are given finallys, which can provide references for the sealing design of precast concrete utility tunnel and promote the further improvement of quality of precast concrete utility tunnel gallery engineering.
结论
参考文献
引用本文
曹生龙.预制混凝土综合管廊接口密封设计方法[J].混凝土与水泥制品,2018(1):35-42.
CAO S L.Methods for Seal Design of Interface of Precast Concrete Utility Tunnel[J].China Concrete and Cement Products,2018(1):35-42.