横向拼接缝胶结缺陷对混塔极限状态受力特性的影响分析
Analysis of the influence of transverse joint bonding imperfections on the ultimate state loading behaviors of hybrid towers
2024年第10期
混凝土塔筒;水平拼接缝;拼接面缺陷;有限元分析;工程算法
Concrete tower; Horizontal joint seam; Splicing interface imperfction; Finite element analysis; Engineering algorithm
2024年第10期
10.19761/j.1000-4637.2024.10.027.07
国家自然科学基金项目(51811540401、52178195)。
张宇豪1,2,吴香国1,3a,3b,*,张明熠4,5,高朝利2,周瑞权4,5,李博洋3a,3b,*
1.福州大学 土木工程学院,福建 福州 350108;2.明阳智慧能源集团股份公司,广东 中山 528437;3.哈尔滨工业大学 a.结构工程灾变与控制教育部重点实验室;b.土木工程智能防灾减灾工业和信息化部重点实验室,黑龙江 哈尔滨 150090;4.一重(黑龙江)风电混塔有限公司,黑龙江 齐齐哈尔 161042;5.上海电气风电集团股份有限公司,上海 200233

张宇豪1,2,吴香国1,3a,3b,*,张明熠4,5,高朝利2,周瑞权4,5,李博洋3a,3b,*

张宇豪,吴香国,张明熠,等.横向拼接缝胶结缺陷对混塔极限状态受力特性的影响分析[J].混凝土与水泥制品,2024(10):27-33.

ZHANG Y H,WU X G,ZHANG M Y,et al.Analysis of the influence of transverse joint bonding imperfections on the ultimate state loading behaviors of hybrid towers[J].China Concrete and Cement Products,2024(10):27-33.

浏览量:
1000
英文名 : Analysis of the influence of transverse joint bonding imperfections on the ultimate state loading behaviors of hybrid towers
刊期 : 2024年第10期
关键词 : 混凝土塔筒;水平拼接缝;拼接面缺陷;有限元分析;工程算法
Key words : Concrete tower; Horizontal joint seam; Splicing interface imperfction; Finite element analysis; Engineering algorithm
刊期 : 2024年第10期
DOI : 10.19761/j.1000-4637.2024.10.027.07
文章编号 :
基金项目 : 国家自然科学基金项目(51811540401、52178195)。
作者 : 张宇豪1,2,吴香国1,3a,3b,*,张明熠4,5,高朝利2,周瑞权4,5,李博洋3a,3b,*
单位 : 1.福州大学 土木工程学院,福建 福州 350108;2.明阳智慧能源集团股份公司,广东 中山 528437;3.哈尔滨工业大学 a.结构工程灾变与控制教育部重点实验室;b.土木工程智能防灾减灾工业和信息化部重点实验室,黑龙江 哈尔滨 150090;4.一重(黑龙江)风电混塔有限公司,黑龙江 齐齐哈尔 161042;5.上海电气风电集团股份有限公司,上海 200233

张宇豪1,2,吴香国1,3a,3b,*,张明熠4,5,高朝利2,周瑞权4,5,李博洋3a,3b,*

张宇豪,吴香国,张明熠,等.横向拼接缝胶结缺陷对混塔极限状态受力特性的影响分析[J].混凝土与水泥制品,2024(10):27-33.

ZHANG Y H,WU X G,ZHANG M Y,et al.Analysis of the influence of transverse joint bonding imperfections on the ultimate state loading behaviors of hybrid towers[J].China Concrete and Cement Products,2024(10):27-33.

摘要
参数
结论
参考文献
引用本文

摘   要:水平拼接缝是混塔的重要装配节点,混塔的水平缝主要通过涂抹环氧树脂结构胶来进行拼接,该拼接方式能较好增强混塔整体性。但是,环氧树脂结构胶施工受天气和人为操作因素的影响较大,常出现涂抹不均匀、不密实等现象,引发系列工程隐患。基于有限元分析软件,以实际工程为背景,采用工程算法研究了混拼接缝缺胶工况对混塔受力特性的影响。结果表明:水平拼接缝缺胶对混凝土节段管片的受力特性影响较大,缺胶比例和缺胶深度会导致塔筒管片边缘局部产生应力集中的现象,当缺胶比例达到8%时,承载力计算值已达到临界值。

Abstract: The horizontal joint seam is an important assembly joint of the hybrid tower. The horizontal joint of the hybrid tower is mainly spliced by applying epoxy resin structural adhesive, which can effectively enhance the overall integrity of the hybrid tower. However, the construction of epoxy resin structural adhesive is greatly affected by weather and human factors, often resulting in uneven and non-dense application, leading to a series of engineering hazards. Based on finite element analysis software and with practical engineering as the background, engineering algorithms were used to analyze the influence of the lack of glue in the mixed joint on the stress status of the hybrid tower. The results show that the lack of glue in the horizontal joint has a significant impact on the stress characteristics of the concrete segment tower. The proportion and depth of missing glue can cause stress concentration at the edges of tower tube segments. When the proportion of missing glue reaches 8%, the calculated bearing capacity has reached the critical value.

扫二维码用手机看
未找到相应参数组,请于后台属性模板中添加

(1)采用有限元软件,对混塔前八环进行了无缺胶状态、缺胶比例5%、8%、10%状态下的分析。通过数值模拟发现,水平缝缺胶会导致混凝土塔筒产生应力集中的现象,当缺胶比例达到8%时,塔筒前三环局部横缝处最大拉应力已超过规定限值,实际工程中可能会出现少量混凝土开裂和崩边的情况。
(2)当混塔缺胶比例达到10%、最大缺胶深度达到100 mm时,通过模型发现塔筒门洞处和前三环横缝处会出现大量的裂缝和压缩的情况,且第一环横缝处最为严重,塔筒无法满足使用要求。
(3)混塔水平缝空鼓、缺胶对结构承载力影响较大。对于不均匀缺胶状态,采用缺胶比例和缺胶最大深度两方面等效出壁厚削弱尺寸,再利用相关标准中承载力计算公式进行计算,当缺胶比例为8%时,承载力计算值已达到临界值。
(4)现有工程算法中无法考虑缺胶不均匀的情况,计算采用平均值的算法,对于较多局部较大缺胶的情况,该算法尚需进行适当折减。

[1] LIU X D,WANG D H,WANG S.Research advances on fabricated shear wall system[J].Materials Science and Engineering,2018,322(4):042022.
[2] BHATTARAI H B.装配式预应力混凝土圆环截面自提升风电塔筒受力性能分析[D].哈尔滨:哈尔滨工业大学,2022.
[3] 张庆天.H160/UHPC风电预应力装配式混合塔筒受力性能分析[D].哈尔滨:哈尔滨工业大学,2021.
[4] 张学森,吴香国,李丹,等.额定风速下装配式UHPC风电塔筒静力与疲劳性能[J].可再生能源,2022,40(8):1066-1072.
[5] 中华人民共和国住房和城乡建设部.混凝土结构设计标准(2024年版):GB 50010—2010[S].北京:中国建筑工业出版社,2010.
[6] 中华人民共和国住房和城乡建设部.高耸结构设计标准:GB 50135—2019[S].北京:中国计划出版社,2019.
[7] 中华人民共和国住房和城乡建设部.无粘结预应力混凝土结构技术规程:JGJ 92—2016[S].北京:中国建筑工业出版社,2016.

张宇豪,吴香国,张明熠,.横向拼接缝胶结缺陷对混塔极限状态受力特性的影响分析[J].混凝土与水泥制品,2024(10):27-33.

ZHANG Y H,WU X G,ZHANG M Y,et al.Analysis of the influence of transverse joint bonding imperfections on the ultimate state loading behaviors of hybrid towers[J].China Concrete and Cement Products,2024(10):27-33.