低负温型管道压浆料工艺性能研究

Study on Processing Performance of Low Negative Temperature Pipeline Slurry

浏览量:

关键词:

低负温;管道压浆料;45min流动度;凝结时间;冬季施工

Key words:

Low or negative temperature; Cable Grout; 45min fluidity; Setting time; Winter construction

刊期:

2017年第4期

DOI:

文章编号:

1000-4637(2017)04-88-04

基金项目:

作者:

朱清华1,费伟全2,谢 松1

单位:

1.北京思达建茂科技发展有限公司,100088;2.绍兴市高速公路建设指挥部,312000

摘要

摘   要:分析了低负温型管道压浆料的技术原理,研究了水灰比、浆体温度、风速、搅拌时间以及储浆罐容积等对凝结时间及流动度经时损失的影响。通过制定合理的压浆施工工艺,以及预应力混凝土梁模拟灌浆后降温试验,验证了管道压浆冬季施工的可行性。

Abstract: The technical principle of low negative temperature pipeline slurry was analyzed, the effects of water cement ratio, slurry temperature, wind speed, stirring time and storage tank volume on the setting time and the loss of fluidity over time were studied. The reasonable process on pressure grouting construction and the test of the prestressed concrete beam to simulate the cooling after grouting were carried out to verify the feasibility of pipeline grouting winter construction.

结论

(1)能否顺利完成压浆施工,取决于浆体45min流动度损失;压浆完成后能否保证后期强度,取决于压浆料的负温水化特性。
(2)根据施工环境温度的不同,可以选用 -10~-5℃、-5~0℃、0~10℃三类GGM低温型压浆料。
(3)可采用约10℃的自然常温水,不需要加热,保证浆体温度入孔前不低于5℃。
(4)选用带有辅助搅拌功能的储浆罐,以保证压浆速度和可操作时间,选用单次搅拌100~200L的搅拌桶。
(5)严格控制水灰比,在保证流动度的前提下,尽量降低水灰比。
(6)浆体压浆完毕需要保证梁体的温度在12h之内不低于-10℃。

参考文献

[1] 中华人民共和国交通运输部.JTG/T F50—2011 公路桥涵施工技术规范[S].北京:人民交通出版社,2011.
[2] 赵锦团,杨富民.低负温压浆材料在连续梁冬施中的应用[J].铁道建筑,2013(3):18-21.
[3] 邓君安,李德栋.硫铝酸盐早强水泥负温下的水化硬化[J]. 硅酸盐学报,1983(11):85-94.
[4] 朱广祥,尹冬梅,朱卫中.负温水泥基灌浆料冬期施工技术[C].中国外加剂协会20 周年论文集:285-288.
 

引用本文

朱清华,费伟全,谢松.低负温型管道压浆料工艺性能研究[J].混凝土与水泥制品,2017(4):88-90+94.

ZHU Q H, FEI W Q, XIE S.Study on Processing Performance of Low Negative Temperature Pipeline Slurry[J].China Concrete and Cement Products,2017(4):88-90+94.


上一个: 重金属复合污染土免烧砖的制备与研究

下一个: 沿海地区桥梁超大零号块裂缝控制技术