苏州混凝土水泥制品研究院有限公司

头部文案

发布时间:2020-01-06 00:00:00
全国建材科技期刊
全国中文核心期刊
中国科技论文统计源期刊
万方数据-数字化期刊群入网期刊
中国学术期刊(光盘版)全文收录期刊
华东地区优秀科技期刊
江苏省期刊方阵“双效期刊”
中国期刊网全文收录期刊
中国科技期刊数据库全文收录期刊
高温高湿环境下方块大体积海工混凝土抗裂性能研究
Study on Cracks Resistance of Cuboid Large Volume Marine Concrete under High Temperature and High Humidity Environment
2017年第6期
高温高湿;方块;大体积;海工混凝土;收缩;抗裂
High temperature and high humidity; Cuboid; Large volume; Marine concrete; Crack resistance
2017年第6期
1000-4637(2017)06-12-04
中建西部建设股份有限公司科技项目(ZJXJ-2015-05)
蒋 震,向佳瑜,冷 政,黄 辉,李 曦,杨琼辉
中建西部建设湖南有限公司,长沙 410000

蒋 震,向佳瑜,冷 政,黄 辉,李 曦,杨琼辉

蒋震,向佳瑜,冷政,等.高温高湿环境下方块大体积海工混凝土抗裂性能研究[J].混凝土与水泥制品,2017(6):12-15.

JIANG Z , XIANG J Y, LENG Z,et al.Study on Cracks Resistance of Cuboid Large Volume Marine Concrete under High Temperature and High Humidity Environment[J].China Concrete and Cement Products,2017(6):12-15.

浏览量:
1000
摘  要:针对南海区域高温高湿环境,采用大粒径粗骨料、小坍落度的配合比设计方法,预埋冷却水管及创新施工养护方式,制备方块大体积海工混凝土。对其收缩性能、热学性能、水化产物、抗裂性能等方面进行分析,并结合工程应用,得出方块大体积海工混凝土抗裂设计及施工的相关措施。研究表明,采用5~31.5mm(占比40%~50%)与31.5~63mm两种连续级配碎石拥有很好的紧密堆积效果,260h收缩率为4.03×10-4,低于5~31.5mm连续级配碎石的260h收缩率4.74×10-4;方块仿真模型和工程实体温度分析检测得出中心最高温度出现在浇筑后40h,接近70℃,中心温度和表层温度最大差值接近25℃;高温高湿环境下采用预埋冷却水管及养护剂+土工布+薄膜+土工布四层体系的养护方式对方块抗裂效果明显。Abstract:Accordingtoexploitedlargeparticleofcoarseaggregate,designedsmallslumpformixproportion,embeddedcoolingwaterpipeandinnovatedconstructionandmaintenance,thelargevolumemarineconcreteofcuboidwasprepared.Theshrinkageproperties,thermalproperties,hydrationproducts,cracksresistance,etcofconcretewereanalyzed,andtheresearchwascombinedwithengineeringapplicationssothatsomerelatedcracksresistancedesignandconstructionmeasuresofconcretewereobtained.Researchresultsshowthattwocontinuousgradationgravelswith5~31.5mm(40%~50%)and31.5~63mmaccumulatedclosely.The260hshrinkageof4.03×10-4whichwaslowerthan5~31.5mmcontinuousgradationconcrete260hshrinkageof4.74×10-4.Simulationresultsshowthatthecentermaximumtemperaturewascloseto70℃whichappearedat40hafterpouring,andthemaximumtemperaturedifferencebetweenthecenterandthesurfaceapproached25°C.Coolingwaterpipeandfoursystemsofcuringagent-geotextile-membrane-geotextilehadgoodeffectoncracksresistanceundertheconditionofhightemperatureandhighhumidity.
英文名 : Study on Cracks Resistance of Cuboid Large Volume Marine Concrete under High Temperature and High Humidity Environment
刊期 : 2017年第6期
关键词 : 高温高湿;方块;大体积;海工混凝土;收缩;抗裂
Key words : High temperature and high humidity; Cuboid; Large volume; Marine concrete; Crack resistance
刊期 : 2017年第6期
DOI :
文章编号 : 1000-4637(2017)06-12-04
基金项目 : 中建西部建设股份有限公司科技项目(ZJXJ-2015-05)
作者 : 蒋 震,向佳瑜,冷 政,黄 辉,李 曦,杨琼辉
单位 : 中建西部建设湖南有限公司,长沙 410000

蒋 震,向佳瑜,冷 政,黄 辉,李 曦,杨琼辉

蒋震,向佳瑜,冷政,等.高温高湿环境下方块大体积海工混凝土抗裂性能研究[J].混凝土与水泥制品,2017(6):12-15.

JIANG Z , XIANG J Y, LENG Z,et al.Study on Cracks Resistance of Cuboid Large Volume Marine Concrete under High Temperature and High Humidity Environment[J].China Concrete and Cement Products,2017(6):12-15.

摘要
参数
结论
参考文献
引用本文

摘   要:针对南海区域高温高湿环境,采用大粒径粗骨料、小坍落度的配合比设计方法,预埋冷却水管及创新施工养护方式,制备方块大体积海工混凝土。对其收缩性能、热学性能、水化产物、抗裂性能等方面进行分析,并结合工程应用,得出方块大体积海工混凝土抗裂设计及施工的相关措施。研究表明,采用5~31.5mm(占比40%~50%)与31.5~63mm两种连续级配碎石拥有很好的紧密堆积效果,260h收缩率为4.03×10-4,低于5~31.5mm 连续级配碎石的260h收缩率4.74×10-4;方块仿真模型和工程实体温度分析检测得出中心最高温度出现在浇筑后40h,接近70℃,中心温度和表层温度最大差值接近25℃;高温高湿环境下采用预埋冷却水管及养护剂+土工布+薄膜+土工布四层体系的养护方式对方块抗裂效果明显。

Abstract: According to exploited large particle of coarse aggregate, designed small slump for mix proportion, embedded cooling water pipe and innovated construction and maintenance, the large volume marine concrete of cuboid was prepared. The shrinkage properties, thermal properties, hydration products, cracks resistance, etc of concrete were analyzed, and the research was combined with engineering applications so that some related cracks resistance design and construction measures of concrete were obtained. Research results show that two continuous gradation gravels with 5~31.5mm (40%~50%) and 31.5~63mm accumulated closely. The 260h shrinkage of 4.03×10-4 which was lower than 5~31.5mm continuous gradation concrete 260h shrinkage of 4.74×10-4. Simulation results show that the center maximum temperature was close to 70℃ which appeared at 40h after pouring, and the maximum temperature difference between the center and the surface approached 25°C. Cooling water pipe and four systems of curing agent-geotextile-membrane-geotextile had good effect on cracks resistance under the condition of high temperature and high humidity.

关键词:
高温高湿;方块;大体积;海工混凝土;收缩;抗裂
扫二维码用手机看
未找到相应参数组,请于后台属性模板中添加
(1)方块混凝土采用5~31.5mm碎石与31.5~63mm两种连续级配碎石,前者占比在40%~50%之间,此时碎石堆积密度较大。非接触收缩试验表明方块混凝土收缩率在0~260h内收缩不断增长。采用5~31.5mm碎石与31.5~63mm两种连续级配碎石的试样Ⅰ收缩更小,260h收缩率为4.03×10-4,而掺5~31.5mm碎石的试样Ⅱ260h收缩率为4.74×10-4,前者更有利于减小混凝土收缩开裂。
(2)通过试验测得方块胶凝材料最大温升值出现在加水拌合后32h左右,最大温升值约为45℃。方块仿真模型推算3d中心温度为55.76℃,7d中心温度为62.49℃。方块实体工程进行温度监测可得浇筑时混凝土入模温度高于30℃,中心最高温度出现在浇筑后约40h,接近70℃,中心温度和表层温度最大差值为24.5℃,理论分析和工程实际较吻合。
(3)基于本工程的高温高湿环境和温度分析可得,采用大粒径骨料、小坍落度的配合比设计方法、预埋冷却水管及养护剂+土工布+薄膜+土工布四层体系的养护方式等措施制得的方块构件表观良好,防裂效果明显,满足设计要求。
[1] 张承志.商品混凝土[M].北京:化学工业出版社,2005.
[2] 陈美祝.水泥基材料组分对早期水化及收缩开裂影响的研究[D].武汉:武汉大学,2004.
[3] 韩建国,阎培渝.低水胶比条件下含硅灰或/和粉煤灰的胶凝材料的水化放热特性[J].铁道科学与工程学报,2006,3(1):70-74.
[4] A. Elahi,P.A.M.Basheer,S.V. Nanukuttan. Mechanical and durability properties of high performance concretes containing supplementary cementitious materials[J].Construction and Building Materials,2010,24:292-299.
[5] 侯雁南.大体积混凝土裂缝控制及处理措施研究[D].济南:山东大学,2007.
[6] 曾德强,钱觉时,吴传明.颗粒级配对矿渣水泥的性能影响研究[J].混凝土与水泥制品,2010(6):1-4.
[7] 江昔平.大体积混凝土温度裂缝控制机理与应用方法研究[D].西安:西安建筑科技大学,2012.

蒋震,向佳瑜,冷政,.高温高湿环境下方块大体积海工混凝土抗裂性能研究[J].混凝土与水泥制品,2017(6):12-15.

JIANG Z , XIANG J Y, LENG Z,et al.Study on Cracks Resistance of Cuboid Large Volume Marine Concrete under High Temperature and High Humidity Environment[J].China Concrete and Cement Products,2017(6):12-15.

相关文件

暂时没有内容信息显示
请先在网站后台添加数据记录。

关注《混凝土与水泥制品》

总访问量 468,401   网站统计

官方微信公众号关闭
苏州混凝土水泥制品研究院有限公司

关于我们    |    联系我们    |    订购杂志    |    回到顶部

版权所有:中国混凝土与水泥制品网  苏ICP备10086386号   网站建设:中企动力 苏州

版权所有:中国混凝土与水泥制品网

苏ICP备10086386号

网站建设:中企动力 苏州