大流动度混杂纤维增强混凝土基本力学性能研究
Research on Mechanical Properties of Hybrid Fiber Reinforced Concrete with High Fluidity
2017年第6期
大流动度混杂纤维增强混凝土;坍落度;抗压强度;劈裂强度
Hybrid fiber reinforced concrete with high fluidity; Slump; Compressive strength; Splitting strength
2017年第6期
1000-4637(2017)06-53-03
杜国伟,刘向坤,杜增强,惠建许
中核混凝土股份有限公司,武汉 430100

杜国伟,刘向坤,杜增强,惠建许

杜国伟,刘向坤,杜增强,等.大流动度混杂纤维增强混凝土基本力学性能研究[J].混凝土与水泥制品,2017(6):53-55.

DU G W, LIU X K, DU Z Q,et al.Research on Mechanical Properties of Hybrid Fiber Reinforced Concrete with High Fluidity[J].China Concrete and Cement Products,2017(6):53-55.

浏览量:
1000
摘 要:在纤维总体积掺率不超过1%的情况下,采用钢纤维、塑钢纤维以及聚丙烯纤维单掺、双掺和三掺配制得到了高流动度纤维增强混凝土;通过稠度试验、抗压试验和劈裂试验,对比分析了纤维混杂方式和纤维混掺比例对基体混凝土工作性能、抗压强度以及劈裂强度的影响规律。结果表明,在混凝土中掺加0.25%~0.35%的引气剂可显著改善混杂纤维增强混凝土的坍落度和坍落扩展度;钢纤维/塑钢纤维/聚丙烯三元混杂可显著提高基体混凝土的抗压强度和劈裂强度最大分别提高了25%和32.61%。;综合考虑混凝土工作性能和力学性能,CF60大流动混杂纤维增强混凝土的纤维混掺比例选定为0.6%SF、0.2%HF、0.11%PPF,引气剂建议掺量为0.35%。 Abstract: With the total volume fraction of the steel fiber below 1%, the hybrid fiber reinforced concrete is prepared by adding steel fiber, steel fiber and polypropylene fiber single, double or triple. Based on the consistency test, compression test and splitting test, the effects of fiber mixing mode and fiber mixing ratio on the working performance, compressive strength and splitting strength of the concrete are analyzed. The results show that the working performance of hybrid fiber reinforced concrete can significantly improve by adding air entraining agent with ration ranging from 0.25% to 0.35%; SF/HF/PPF HFRC can significantly improve the compressive strength and splitting strength of the matrix concrete with 25% and 32.61% respectively. On the basis of the working performance and mechanical property, the most suitable fibers proportion of CF60 is 0.6% SF, 0.2% HF and 0.11% PPF .And the reasonable ratio of air entraining agent is 0.35%.
英文名 : Research on Mechanical Properties of Hybrid Fiber Reinforced Concrete with High Fluidity
刊期 : 2017年第6期
关键词 : 大流动度混杂纤维增强混凝土;坍落度;抗压强度;劈裂强度
Key words : Hybrid fiber reinforced concrete with high fluidity; Slump; Compressive strength; Splitting strength
刊期 : 2017年第6期
DOI :
文章编号 : 1000-4637(2017)06-53-03
基金项目 :
作者 : 杜国伟,刘向坤,杜增强,惠建许
单位 : 中核混凝土股份有限公司,武汉 430100

杜国伟,刘向坤,杜增强,惠建许

杜国伟,刘向坤,杜增强,等.大流动度混杂纤维增强混凝土基本力学性能研究[J].混凝土与水泥制品,2017(6):53-55.

DU G W, LIU X K, DU Z Q,et al.Research on Mechanical Properties of Hybrid Fiber Reinforced Concrete with High Fluidity[J].China Concrete and Cement Products,2017(6):53-55.

摘要
参数
结论
参考文献
引用本文

摘   要:在纤维总体积掺率不超过1%的情况下,采用钢纤维、塑钢纤维以及聚丙烯纤维单掺、双掺和三掺配制得到了高流动度纤维增强混凝土;通过稠度试验、抗压试验和劈裂试验,对比分析了纤维混杂方式和纤维混掺比例对基体混凝土工作性能、抗压强度以及劈裂强度的影响规律。结果表明,在混凝土中掺加0.25%~0.35%的引气剂可显著改善混杂纤维增强混凝土的坍落度和坍落扩展度;钢纤维/塑钢纤维/聚丙烯三元混杂可显著提高基体混凝土的抗压强度和劈裂强度最大分别提高了25%和32.61%。;综合考虑混凝土工作性能和力学性能,CF60大流动混杂纤维增强混凝土的纤维混掺比例选定为0.6%SF、0.2%HF、0.11%PPF,引气剂建议掺量为0.35%。

Abstract: With the total volume fraction of the steel fiber below 1%, the hybrid fiber reinforced concrete is prepared by adding steel fiber, steel fiber and polypropylene fiber single, double or triple. Based on the consistency test, compression test and splitting test, the effects of fiber mixing mode and fiber mixing ratio on the working performance, compressive strength and splitting strength of the concrete are analyzed. The results show that the working performance of hybrid fiber reinforced concrete can significantly improve by adding air entraining agent with ration ranging from 0.25% to 0.35%; SF/HF/PPF HFRC can significantly improve the compressive strength and splitting strength of the matrix concrete with 25% and 32.61% respectively. On the basis of the working performance and mechanical property, the most suitable fibers proportion of CF60 is 0.6% SF, 0.2% HF and 0.11% PPF .And the reasonable ratio of air entraining agent is 0.35%.

关键词:
大流动度混杂纤维增强混凝土;坍落度;抗压强度;劈裂强度
扫二维码用手机看
未找到相应参数组,请于后台属性模板中添加
(1)掺加0.4%±0.1%的引气剂可确保掺入不超过1%的混杂纤维后,混凝土的坍落度和坍落扩展度分别稳定在160~200mm和280~380mm,满足大流动度的要求。
(2)相对于SF/PPF二元混杂,SF/HF/PPF三元组合混凝土的拌合物具备更好的流动性,基于工作性能最佳的纤维混掺比例为0.4%SF、0.4%HF、0.11%PPF。
(3)混杂纤维的掺入可显著提高混凝土的抗压强度和劈裂抗拉强度,抗压强度和劈裂抗拉强度最大分别提高了25%和32.61%,基于综合力学性能最佳的纤维混掺比例为0.6%SF、0.2%HF、0.11%PPF。
(4)纤维的掺入可以改善混凝土的脆性,各配比混凝土试件的拉压比维持在1.22/20~1.35/20。
(5)综合考虑混凝土工作性能和力学性能,C60大流动混杂纤维增强混凝土的纤维混掺比例选定为0.6%SF、0.2%HF、0.11%PPF,引气剂建议掺量为0.35%。
[1] Giaccio G, Tobes J M, Zerbino R.Use of small beams to obtain design parameters of fiber reinforced concrete[J].Cement & Concrete Composites,2008,30:297-306.
[2] Seung Hun Park, Dong Joo Kim, Gum Sung Ryu, et al. Tensile behavior of Ultra High Performance Hybrid Fiber Reinforced Concrete[J]. Cement & Concrete Composites,2012,34:172-184.
[3] 邓宗才,李建辉,刘国栋.混杂粗纤维增强混凝土力学特性试验研究[J].混凝土,2006(8):50-55.
[4] 赵亮平,高丹盈,朱海堂.钢纤维对混凝土强度和韧性的影响[J].华北水利水电学院学报,2012,33(6):29-32.
[5] 高淑玲,田稳苓,张二龙.混杂纤维高性能混凝土在桥面铺装中的应用研究[J].混凝土与水泥制品,2010(3):55-59.
[6] 梅国栋,李继祥,刘肖凡,等.混杂纤维混凝土抗弯性能及混杂效应试验研究[J].混凝土,2013(2):21-24.
[7] 高丹盈,赵亮平,冯虎,等.钢纤维混凝土弯曲韧性及其评价方法[J].建筑材料学报,2014,17(5):783-789.
[8] 王志杰,孟祥磊,王奇,等.钢纤维混凝土弯曲韧性试验研究[J].混凝土,2014(3):71-74. 
[9] 孙海燕,何真.混杂纤维对混凝土力学及抗裂性能的影响[J].混凝土与水泥制品,2009(2):48-51.
[10] 卢哲安,邹尤,任志刚,等.纤维高强混凝土弯曲韧性试验研究[J].混凝土,2010(3):5-7.
[11] 王海超,刘校源.较高韧性混杂纤维混凝土弯曲抗拉性能试验研究[J].混凝土与水泥制品,2011(4):46-49.
[12] 闫长旺,贾金青,张菊.钢纤维增强超高强混凝土拉压比试验研究[J].大连理工大学学报,2012,52(2):233-238.
[13] 夏冬桃,刘向坤,夏广政,等.混杂纤维增强高性能混凝土弯曲韧性研究[J].华中科技大学学报:自然科学版,2013,41(6):108-112. 

杜国伟,刘向坤,杜增强,.大流动度混杂纤维增强混凝土基本力学性能研究[J].混凝土与水泥制品,2017(6):53-55.

DU G W, LIU X K, DU Z Q,et al.Research on Mechanical Properties of Hybrid Fiber Reinforced Concrete with High Fluidity[J].China Concrete and Cement Products,2017(6):53-55.

相关文件

暂时没有内容信息显示
请先在网站后台添加数据记录。

关注《混凝土与水泥制品》

总访问量 468,401   网站统计

官方微信公众号关闭
苏州混凝土水泥制品研究院有限公司

关于我们    |    联系我们    |    订购杂志    |    回到顶部

版权所有:中国混凝土与水泥制品网  苏ICP备10086386号   网站建设:中企动力 苏州

版权所有:中国混凝土与水泥制品网

苏ICP备10086386号

网站建设:中企动力 苏州