无机保温砂浆内外组合保温系统结合外墙隔热涂料的热工性能研究
Research on Thermal Properties of Inorganic Insulation Mortar Internal and External Composite Insulation System combining with
关键词:
无机保温砂浆;外墙隔热涂料;热工性能;防潮设计
Key words:
Inorganic insulation mortar; Exterior wall heat insulation coating; Thermal performance; Moistureproof design
刊期:
2017年第9期
DOI:
文章编号:
000-4637(2017)09-60-03
基金项目:
作者:
华治国,朱 悦,王吉霖
单位:
上海建科检验有限公司,201108
摘要
摘 要:根据上海市建筑节能相关规定和要求,进行了墙体构造方案的热工计算和分析,提出了适用于夏热冬冷地区的无机保温砂浆内外组合保温系统结合外墙隔热涂料的复合混凝土外墙构造方案。
Abstract: According to the relevant regulations and requirements of building energy efficiency in Shanghai, the thermal calculation and analysis of the wall construction scheme is carried out, the concrete wall construction scheme of inorganic insulation mortar internal and external composite insulation system with exterior wall heat insulation coating that can be used in hot summer and cold winter zone is put forward.
结论
参考文献
引用本文
华治国,朱悦,王吉霖.无机保温砂浆内外组合保温系统结合外墙隔热涂料的热工性能研究[J].混凝土与水泥制品,2017(9):60-62.
HUA Z G, ZHU Y, WANG J L.Research on Thermal Properties of Inorganic Insulation Mortar Internal and External Composite Insulation System combining with Exterior Wall Heat Insulation Coating[J].China Concrete and Cement Products,2017(9):60-62.