无机保温砂浆内外组合保温系统结合外墙隔热涂料的热工性能研究

Research on Thermal Properties of Inorganic Insulation Mortar Internal and External Composite Insulation System combining with

浏览量:

关键词:

无机保温砂浆;外墙隔热涂料;热工性能;防潮设计

Key words:

Inorganic insulation mortar; Exterior wall heat insulation coating; Thermal performance; Moistureproof design

刊期:

2017年第9期

DOI:

文章编号:

000-4637(2017)09-60-03

基金项目:

作者:

华治国,朱 悦,王吉霖

单位:

上海建科检验有限公司,201108

摘要

摘   要:根据上海市建筑节能相关规定和要求,进行了墙体构造方案的热工计算和分析,提出了适用于夏热冬冷地区的无机保温砂浆内外组合保温系统结合外墙隔热涂料的复合混凝土外墙构造方案。

Abstract: According to the relevant regulations and requirements of building energy efficiency in Shanghai, the thermal calculation and analysis of the wall construction scheme is carried out, the concrete wall construction scheme of inorganic insulation mortar internal and external composite insulation system with exterior wall heat insulation coating that can be used in hot summer and cold winter zone is put forward.

结论

(1)结合了外墙隔热涂料的无机保温砂浆内外组合保温混凝土外墙方案能满足当前上海市及周边地区居住建筑节能要求的热工设计要求,可消除无机保温材料在内保温时容易产生内部冷凝进而降低甚至失去保温节能性能的弊病。
(2)随着建筑节能设计标准的提升,目前建筑市场上有很大一部分建筑节能材料已无法单独应用来满足墙体的保温隔热及节能要求,但通过合理的组合和科学的设计建立的墙体能满足建筑节能设计要求。
(3)目前的住宅建筑节能设计标准在建筑外墙的墙体热工设计时,只考虑其保温和隔热而不注重墙体防潮性能,不利于设计出能充分发挥保温材料保温隔热和节能功能的墙体,建议在进行节能建筑热工设计时增加建筑外墙墙体的防潮性能设计。

参考文献

[1] 中华人民共和国住房和城乡建设部.GB 50176-1993民用建筑热工设计规范[S].北京:中国建筑工业出版社,1993.
[2] 同济大学,上海市建筑科学研究院(集团)有限公司.DG/TJ 08-2088—2011无机保温砂浆系统应用技术规程[S].上海:同济大学出版社,2011.
[3] 上海市建筑科学研究院(集团)有限公司,上海市建筑建材业市场管理总站. DGJ 08-205—2015 居住建筑节能设计标准[S].上海:同济大学出版社,2015.
[4] 柳孝图.建筑物理[M].北京:中国建筑工业出版社,2014.
 

引用本文

华治国,朱悦,王吉霖.无机保温砂浆内外组合保温系统结合外墙隔热涂料的热工性能研究[J].混凝土与水泥制品,2017(9):60-62.

HUA Z G, ZHU Y, WANG J L.Research on Thermal Properties of Inorganic Insulation Mortar Internal and External Composite Insulation System combining with Exterior Wall Heat Insulation Coating[J].China Concrete and Cement Products,2017(9):60-62.


上一个: 基于HyperMesh和LS-Dyna的径向挤压制管机成型头仿真分析

下一个: 新型保温承重砌块砌体抗压性能试验研究

相关文件