联肢剪力墙结构连梁的抗震试验研究
Experimental Study on Seismic Behavior of Joint Beam with Double Shear Wall Structure
2019年第8期
联肢剪力墙;RC连梁;消能连梁;抗震试验
Coupled shear wall; RC coupling beam; Coupling beam energy dissipation; Seismic test
2019年第8期
10.19761/j.1000-4637.2019.08.072.05
国家自然科学基金项目(51408144)
郑 娟
扬州市职业大学,225009

郑 娟

郑娟.联肢剪力墙结构连梁的抗震试验研究[J].混凝土与水泥制品,2019(8):72-76.

ZHENG J.Experimental Study on Seismic Behavior of Joint Beam with Double Shear Wall Structure[J].China Concrete and Cement Products,2019(8):72-76.

浏览量:
1000
摘 要:为研究双肢剪力墙结构大剪跨比(μ≥2.5)钢筋混凝土耗能连梁的力学性能。设计了3个剪跨比为3.0的钢筋混凝土连梁构件,其中2个为普通混凝土连梁,1个为设置消能装置的连梁,通过低周往复加载试验,对比分析了裂缝发展、连梁转角、荷载-位移曲线、骨架曲线、构件刚度以及耗能能力。分析结果表明,采用金属耗能装置的钢筋混凝土连梁可以有效降低连梁自身混凝土段和墙肢的损伤,主要变形集中在金属耗能装置中,可以很好地实现震后构件的快速更换,带阻尼器连梁没有出现普通连梁承载力超强的问题。 Abstract: In order to study the mechanical properties of double shear wall structure with large shear-span ratio, three reinforced concrete beam connectors with a shear to span ratio of 3.0 were designed, and two of them were ordinary concrete beams and one was a beam with an energy dissipation device. Through low-cycle reciprocating loading test, the crack development, beam Angle, load-displacement curve, skeleton curve, component stiffness and energy dissipation capacity were compared and analyzed. The analysis results show that the reinforced concrete beam with metal energy dissipation device can effectively reduce the damage of the concrete section and the wall limb of the beam itself, and the main deformation is concentrated in the metal energy dissipation device, which can well realize the rapid replacement of the components after the earthquake, and there is no problem of super bearing capacity of ordinary connecting beams with dampers.
英文名 : Experimental Study on Seismic Behavior of Joint Beam with Double Shear Wall Structure
刊期 : 2019年第8期
关键词 : 联肢剪力墙;RC连梁;消能连梁;抗震试验
Key words : Coupled shear wall; RC coupling beam; Coupling beam energy dissipation; Seismic test
刊期 : 2019年第8期
DOI : 10.19761/j.1000-4637.2019.08.072.05
文章编号 :
基金项目 : 国家自然科学基金项目(51408144)
作者 : 郑 娟
单位 : 扬州市职业大学,225009

郑 娟

郑娟.联肢剪力墙结构连梁的抗震试验研究[J].混凝土与水泥制品,2019(8):72-76.

ZHENG J.Experimental Study on Seismic Behavior of Joint Beam with Double Shear Wall Structure[J].China Concrete and Cement Products,2019(8):72-76.

摘要
参数
结论
参考文献
引用本文

摘   要:为研究双肢剪力墙结构大剪跨比(μ≥2.5)钢筋混凝土耗能连梁的力学性能。设计了3个剪跨比为3.0的钢筋混凝土连梁构件,其中2个为普通混凝土连梁,1个为设置消能装置的连梁,通过低周往复加载试验,对比分析了裂缝发展、连梁转角、荷载-位移曲线、骨架曲线、构件刚度以及耗能能力。分析结果表明,采用金属耗能装置的钢筋混凝土连梁可以有效降低连梁自身混凝土段和墙肢的损伤,主要变形集中在金属耗能装置中,可以很好地实现震后构件的快速更换,带阻尼器连梁没有出现普通连梁承载力超强的问题。
Abstract: In order to study the mechanical properties of double shear wall structure with large shear-span ratio, three reinforced concrete beam connectors with a shear to span ratio of 3.0 were designed, and two of them were ordinary concrete beams and one was a beam with an energy dissipation device. Through low-cycle reciprocating loading test, the crack development, beam Angle, load-displacement curve, skeleton curve, component stiffness and energy dissipation capacity were compared and analyzed. The analysis results show that the reinforced concrete beam with metal energy dissipation device can effectively reduce the damage of the concrete section and the wall limb of the beam itself, and the main deformation is concentrated in the metal energy dissipation device, which can well realize the rapid replacement of the components after the earthquake, and there is no problem of super bearing capacity of ordinary connecting beams with dampers.

关键词:
联肢剪力墙;RC连梁;消能连梁;抗震试验
扫二维码用手机看
未找到相应参数组,请于后台属性模板中添加

(1)在进行最大承载力和屈服的计算时,使用的是消能连梁承载力设计公式,提高了计算结果的准确性。
(2)为了降低设置金属耗能装置连梁中混凝土的破坏比例,采用强度折减的方法对消能连梁进行设计,可以做到消能连梁的刚度比普通混凝土连梁的刚度小,但是对于刚度较小的大剪跨比较大的连梁可能影响在多遇地震作用下的弹性设计。
(3)双肢剪力墙带阻尼器连梁在减震效果上比传统钢筋混凝土连梁好,特别是结构进入大变形阶段优势更加明显。

[1] 吴学敏.高层建筑剪力墙中连梁设计的探讨[J].建筑结构学报,1995,16(1):77-78.
[2] 龚炳年,方鄂华.反复荷载下联肢剪力墙结构连系梁的性能[J].建筑结构学报,1988,9(1):34-41.
[3] 缪志伟.钢筋混凝土框架剪力墙结构基于能量抗震设计方法研究[D].北京:清华大学,2009.
[4] 潘超,翁大根.连梁内设置竖向变形阻尼器的耗能剪力墙体系减震分析与设计[J].建筑结构学报,2012,33(10):39-46.
[5] 纪晓东,王彦栋,马琦峰,等.可更换钢连梁抗震性能试验研究[J].建筑结构学报,2015,36(10):1-10.
[6]  中华人民共和国住房和城乡建设部.GB 50010—2010 混凝土结构设计规范[S].北京:中国建筑工业出版社,2010.
[7] HITAKA T, MATSUI C.Experimental Study on Steel Shear Wall with Slits[J]. Journal of Structural Engineering,2003,129(5):586-595.
[8] 王啸霆.铰支墙—框架新型结构体系的损伤控制研究[D].北京:中国地震局工程力学研究所,2017.
[9]  施唯.钢筋混凝土连梁的破坏机制与损伤控制研究[D].北京:中国地震局工程力学研究所,2015.
[10] 师骁,王彦栋,曲哲,等.含摩擦阻尼器钢连梁的往复加载试验[J].工程学,2016,33(S1):156-160.
[11] ROJAS P,RICLES J M,SAUSE R,et al.Performance of post-tensioned steel moment resisting frames with friction devices[J].Journal of Structural Engineering,2005(4):529-540.
[12] REMY D, LEQUESNE, GUSTAVO J,et al.WIGHT.Seismic Behavior and Detailing of High-Performance Fiber-Reinforced Concrete Coupling Beams and Coupled Wall Systems[J].Journal of Structural Engineering,2013,139:1362-1370.
 

郑娟.联肢剪力墙结构连梁的抗震试验研究[J].混凝土与水泥制品,2019(8):72-76.

ZHENG J.Experimental Study on Seismic Behavior of Joint Beam with Double Shear Wall Structure[J].China Concrete and Cement Products,2019(8):72-76.

 

相关文件

暂时没有内容信息显示
请先在网站后台添加数据记录。

关注《混凝土与水泥制品》

总访问量 468,401   网站统计

官方微信公众号关闭
苏州混凝土水泥制品研究院有限公司

关于我们    |    联系我们    |    订购杂志    |    回到顶部

版权所有:中国混凝土与水泥制品网  苏ICP备10086386号   网站建设:中企动力 苏州

版权所有:中国混凝土与水泥制品网

苏ICP备10086386号

网站建设:中企动力 苏州